Comprehensive investigation of rooftop photovoltaic power plants with monocrystalline polycrystalline and thin-film technologies for exergy economic and environmental assessments

This research aims to conduct an exergy, economic, and environmental analysis of a 6.57 kW<sub>p</sub> rooftop photovoltaic (PV) power plant that combines different PV technologies, comprising 2 kW<sub>p</sub> of poly-crystalline (p-Si), 1.87 kW<sub>p</sub> of mono-crystalline (m-Si), and 2.7 kW<sub>p</sub> of thin-film amorphous silicon (a-Si) technologies. A comprehensive assessment was conducted to evaluate the environmental and techno-economic parameters of a PV plant system. This study is based on the performance data obtained over four years of energy production under the weather conditions of Kuala Lumpur, Malaysia. The embodied energy required for the manufacturing of the PV power plant was estimated using embodied energy indices available in the literature. Additionally, a detailed economic evaluation was conducted based on the electricity costs in Malaysia. Moreover, the environmental impact was assessed over the plant's life cycle, considering the emission factors of coal power plants. Results indicate that the exergy payback time for the different technologies i.e., m-Si, p-Si, a-Si, when operated individually, and when combined within a single PV system, are found to be ~ [Formula: see text], and [Formula: see text] years, respectively. Over its life cycle, it was found that the PV plant emits about [Formula: see text]. Emission breakdown analysis has revealed that the manufacturing process of the m-Si, p-Si, a-Si, and the monitoring systems contribute to [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text] of [Formula: see text] emissions, respectively. However, the PV power plant could offset about [Formula: see text] annually, equivalent to the emission of a car over approximately 3 years. This study offers critical insights into the exergy efficiency, environmental impact, and economic viability of a grid-connected rooftop PV power plant that integrates multiple PV technologies under tropical climate conditions.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-03
DOI
https://doi.org/10.1038/s41598-025-99939-0
Citations
5
Primary Topic
Photovoltaic Systems and Sustainability
Type
article
Field-Weighted Citation Impact
4.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive investigation of rooftop photovoltaic power plants with monocrystalline polycrystalline and thin-film technologies for exergy economic and environmental assessments

Kok Soon Tey, Abdullahi Mohamed Samatar, Putri Nor Liyana Mohamad Radzi, Saad Mekhilef et al.
5 citations
Scientific Reports
Photovoltaic Systems and Sustainability
4.00
article

Comprehensive investigation of rooftop photovoltaic power plants with monocrystalline polycrystalline and thin-film technologies for exergy economic and environmental assessments

Kok Soon Tey, Abdullahi Mohamed Samatar, Putri Nor Liyana Mohamad Radzi, Saad Mekhilef, Obaid Alshammari, Abdelhak Lekbir, Samir Hassani
article en
5 citations

Abstract

This research aims to conduct an exergy, economic, and environmental analysis of a 6.57 kW<sub>p</sub> rooftop photovoltaic (PV) power plant that combines different PV technologies, comprising 2 kW<sub>p</sub> of poly-crystalline (p-Si), 1.87 kW<sub>p</sub> of mono-crystalline (m-Si), and 2.7 kW<sub>p</sub> of thin-film amorphous silicon (a-Si) technologies. A comprehensive assessment was conducted to evaluate the environmental and techno-economic parameters of a PV plant system. This study is based on the performance data obtained over four years of energy production under the weather conditions of Kuala Lumpur, Malaysia. The embodied energy required for the manufacturing of the PV power plant was estimated using embodied energy indices available in the literature. Additionally, a detailed economic evaluation was conducted based on the electricity costs in Malaysia. Moreover, the environmental impact was assessed over the plant's life cycle, considering the emission factors of coal power plants. Results indicate that the exergy payback time for the different technologies i.e., m-Si, p-Si, a-Si, when operated individually, and when combined within a single PV system, are found to be ~ [Formula: see text], and [Formula: see text] years, respectively. Over its life cycle, it was found that the PV plant emits about [Formula: see text]. Emission breakdown analysis has revealed that the manufacturing process of the m-Si, p-Si, a-Si, and the monitoring systems contribute to [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text] of [Formula: see text] emissions, respectively. However, the PV power plant could offset about [Formula: see text] annually, equivalent to the emission of a car over approximately 3 years. This study offers critical insights into the exergy efficiency, environmental impact, and economic viability of a grid-connected rooftop PV power plant that integrates multiple PV technologies under tropical climate conditions.

Scientific ReportsVol. 15(1)
University of Malaya (MY), University of Ha'il (SA), Renewable Energy Development Center (DZ), Swinburne University of Technology (AU)
Responsible consumption and production
Openalex Percentile: Top 7%
Photovoltaic Systems and Sustainability
4.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.