Persistent median artery accidentally identified during radial artery catheterization: A case report

Radial artery catheterization is commonly performed using the pulse palpation method. However, anatomical variations, such as the persistent median artery-an embryonic structure that may persist into adulthood-can complicate this procedure. A 47-year-old female scheduled for laparoscopic surgery required radial artery catheterization for hemodynamic monitoring. Multiple attempts to place a 22-gauge catheter in the left radial artery were unsuccessful. During the procedure, a pulsating vessel was identified on the ulnar side of the radial artery. Vascular visualization devices revealed the presence of a persistent median artery, accompanied by the median nerve. Subsequently, real-time ultrasound guidance facilitated successful radial artery catheterization. Anatomical variations, such as the persistent median artery, can complicate radial artery catheterization and are not easily identified through pulse palpation alone. The use of vascular visualization devices is recommended to identify and navigate such variations, ensuring accurate catheter placement.

Authors

Institutions

Publication Details

Journal
The Journal of Vascular Access
Published
2025-05-03
DOI
https://doi.org/10.1177/11297298251331994
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Persistent median artery accidentally identified during radial artery catheterization: A case report

Tetsuya Uchino, Sunao Nakamura, Shigekiyo Matsumoto
The Journal of Vascular Access
Central Venous Catheters and Hemodialysis
article

Persistent median artery accidentally identified during radial artery catheterization: A case report

Tetsuya Uchino, Sunao Nakamura, Shigekiyo Matsumoto
article en

Abstract

Radial artery catheterization is commonly performed using the pulse palpation method. However, anatomical variations, such as the persistent median artery-an embryonic structure that may persist into adulthood-can complicate this procedure. A 47-year-old female scheduled for laparoscopic surgery required radial artery catheterization for hemodynamic monitoring. Multiple attempts to place a 22-gauge catheter in the left radial artery were unsuccessful. During the procedure, a pulsating vessel was identified on the ulnar side of the radial artery. Vascular visualization devices revealed the presence of a persistent median artery, accompanied by the median nerve. Subsequently, real-time ultrasound guidance facilitated successful radial artery catheterization. Anatomical variations, such as the persistent median artery, can complicate radial artery catheterization and are not easily identified through pulse palpation alone. The use of vascular visualization devices is recommended to identify and navigate such variations, ensuring accurate catheter placement.

The Journal of Vascular AccessVol. 27(1)
Oita University (JP)
Good health and well-being
Openalex Percentile: Top 85%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.