Single-Objective Airy Light-Sheet Imaging

Despite its massive potential, standard light-sheet imaging (LSI) faces key challenges, such as the incompatibility with common sample mounting techniques and low-resolution imaging. Single-objective LSI attempts to address these issues but often suffers from limited fields-of-view and throughput rates, or requires multiple optics that increase costs, alignment complexity, and losses. To overcome these challenges of standard single-objective LSI, we introduce single-objective Airy light-sheet imaging (SoALSI). SoALSI leverages the extraordinary self-acceleration properties of the Airy beam, achieving 5× higher imaging rates and enhanced imaging efficiency than standard single-objective LSI. We demonstrate SoALSI’s versatility through rigorous contrast and resolution characterizations and by high-resolution imaging of diverse biological specimens, including malaria parasite-infected red blood cells and plant root tissue. SoALSI seamlessly integrates with any standard inverted microscope frame, enabling broader accessibility for the bioimaging community to explore biological processes in a wide range of specimens with enhanced resolution and imaging contrast.

Authors

Institutions

Publication Details

Journal
ACS Photonics
Published
2025-05-03
DOI
https://doi.org/10.1021/acsphotonics.4c02078
Citations
3
Primary Topic
Orbital Angular Momentum in Optics
Type
article
Field-Weighted Citation Impact
3.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-Objective Airy Light-Sheet Imaging

Andreas E. Vasdekis, Haokun Luo, Shirley Luckhart, Ramachandran Kasu et al.
3 citations
ACS Photonics
Orbital Angular Momentum in Optics
3.74
article

Single-Objective Airy Light-Sheet Imaging

Andreas E. Vasdekis, Haokun Luo, Shirley Luckhart, Ramachandran Kasu, Demetrios N. Christodoulides
article en
3 citations

Abstract

Despite its massive potential, standard light-sheet imaging (LSI) faces key challenges, such as the incompatibility with common sample mounting techniques and low-resolution imaging. Single-objective LSI attempts to address these issues but often suffers from limited fields-of-view and throughput rates, or requires multiple optics that increase costs, alignment complexity, and losses. To overcome these challenges of standard single-objective LSI, we introduce single-objective Airy light-sheet imaging (SoALSI). SoALSI leverages the extraordinary self-acceleration properties of the Airy beam, achieving 5× higher imaging rates and enhanced imaging efficiency than standard single-objective LSI. We demonstrate SoALSI’s versatility through rigorous contrast and resolution characterizations and by high-resolution imaging of diverse biological specimens, including malaria parasite-infected red blood cells and plant root tissue. SoALSI seamlessly integrates with any standard inverted microscope frame, enabling broader accessibility for the bioimaging community to explore biological processes in a wide range of specimens with enhanced resolution and imaging contrast.

ACS PhotonicsVol. 12(5)
University of Southern California (US), Pacific Northwest National Laboratory (US), University of Idaho (US), California Southern University (US), Environmental Molecular Sciences Laboratory (US), Institute of Entomology (CZ)
Biological and Environmental Research
Openalex Percentile: Top 8%
Orbital Angular Momentum in Optics
3.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Single-Objective Airy Light-Sheet Imaging — Andreas E. Vasdekis, Haokun Luo, et al. · ACS Photonics (2025) | TGRS Research Map | TGRS