Profitability analysis of H2 production by water electrolysis in an integrated oxy-fuel combustion thermal power plant
Integrating oxy-fuel combustion into waste-to-energy power plants with electrolysis is a promising strategy to address waste management and reduce CO 2 emissions. However, the economic implication of retrofitting a combined heat and power plant into oxy-fuel should be compared to its conventional air-fired strategy to enhance investments for carbon capture strategies. This paper investigates the integration of a waste-to-energy combined heat and power plant with an alkaline electrolyzer for oxy-fuel combustion and its economic competitiveness against the non-retrofitted air-fired combined heat and power plant. An air-fired power plant and its retrofitting into oxy-fuel combustion were modeled using AspenPlus based on the data from a real power plant (250 MW th ), situated in Finland. Retrofitting the chosen air-fired power plant required additional electric power of 320 MW el , supplemented by the grid, to satisfy the demand of the electrolyzer (372 MW). Nevertheless, the implementation of oxy-fuel combustion and waste heat recovery from the electrolyzer increased the district heating output from 154 to 350 MW th . Owing to a sensitivity analysis, it was found that the optimal exploitation of the thermal energy in the flue gas was achieved with a recirculation fraction of 70 %–80 % (70.5 % in this study). The oxy-fuel system produced a mass flow rate of CO 2 equal to 18.4 kg/s with a purity of 99.2 mol% and 2.06 kg/s of pure H 2 with a molar ratio of 2.5:1 (H 2 –CO 2 ). The price of H 2 , produced by the oxy-fuel retrofitted system, to obtain the same profit as the conventional air-fired combined and heat power plant was 1.57 EUR/kg. Due to its economic competitiveness, the proposed retrofitting into oxy-fuel combustion can be implemented on large scale, thus making a significant impact on reducing CO 2 emissions. • Retrofitting into oxy-fuel combustion (250 MW th ) required an electrolyzer with a capacity of 372 MW. • Waste heat recovery from electrolysis increased the district heating output by 126 %. • The system produced H 2 and CO 2 with mass flow rates of 2.1 and 18.4 kg/s, respectively. • The oxy-fuel system has the same profit as the air-fired one if H 2 is sold at 1.57 EUR/kg.
Authors
- Margolis Re (ORCID: https://orcid.org/0000-0001-5091-7624)
- Timo Laukkanen (ORCID: https://orcid.org/0000-0001-6726-0833)
- Shouzhuang Li (ORCID: https://orcid.org/0000-0001-7646-5929)
- Mika Järvinen
Institutions
- Ghent University (BE)
- Aalto University (FI)
Publication Details
- Journal
- Fuel
- Published
- 2025-05-03
- DOI
- https://doi.org/10.1016/j.fuel.2025.135544
- Citations
- 8
- Primary Topic
- Hybrid Renewable Energy Systems
- Type
- article
- Field-Weighted Citation Impact
- 4.25
Funders
- KAUTE-Säätiö
- Aalto-Yliopisto
- Tekniikan Edistämissäätiö