Profitability analysis of H2 production by water electrolysis in an integrated oxy-fuel combustion thermal power plant

Integrating oxy-fuel combustion into waste-to-energy power plants with electrolysis is a promising strategy to address waste management and reduce CO 2 emissions. However, the economic implication of retrofitting a combined heat and power plant into oxy-fuel should be compared to its conventional air-fired strategy to enhance investments for carbon capture strategies. This paper investigates the integration of a waste-to-energy combined heat and power plant with an alkaline electrolyzer for oxy-fuel combustion and its economic competitiveness against the non-retrofitted air-fired combined heat and power plant. An air-fired power plant and its retrofitting into oxy-fuel combustion were modeled using AspenPlus based on the data from a real power plant (250 MW th ), situated in Finland. Retrofitting the chosen air-fired power plant required additional electric power of 320 MW el , supplemented by the grid, to satisfy the demand of the electrolyzer (372 MW). Nevertheless, the implementation of oxy-fuel combustion and waste heat recovery from the electrolyzer increased the district heating output from 154 to 350 MW th . Owing to a sensitivity analysis, it was found that the optimal exploitation of the thermal energy in the flue gas was achieved with a recirculation fraction of 70 %–80 % (70.5 % in this study). The oxy-fuel system produced a mass flow rate of CO 2 equal to 18.4 kg/s with a purity of 99.2 mol% and 2.06 kg/s of pure H 2 with a molar ratio of 2.5:1 (H 2 –CO 2 ). The price of H 2 , produced by the oxy-fuel retrofitted system, to obtain the same profit as the conventional air-fired combined and heat power plant was 1.57 EUR/kg. Due to its economic competitiveness, the proposed retrofitting into oxy-fuel combustion can be implemented on large scale, thus making a significant impact on reducing CO 2 emissions. • Retrofitting into oxy-fuel combustion (250 MW th ) required an electrolyzer with a capacity of 372 MW. • Waste heat recovery from electrolysis increased the district heating output by 126 %. • The system produced H 2 and CO 2 with mass flow rates of 2.1 and 18.4 kg/s, respectively. • The oxy-fuel system has the same profit as the air-fired one if H 2 is sold at 1.57 EUR/kg.

Authors

Institutions

Publication Details

Journal
Fuel
Published
2025-05-03
DOI
https://doi.org/10.1016/j.fuel.2025.135544
Citations
8
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
4.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Profitability analysis of H2 production by water electrolysis in an integrated oxy-fuel combustion thermal power plant

Margolis Re, Timo Laukkanen, Shouzhuang Li, Mika Järvinen
8 citations
Fuel
Hybrid Renewable Energy Systems
4.25
article

Profitability analysis of H2 production by water electrolysis in an integrated oxy-fuel combustion thermal power plant

Margolis Re, Timo Laukkanen, Shouzhuang Li, Mika Järvinen
article en
8 citations

Abstract

Integrating oxy-fuel combustion into waste-to-energy power plants with electrolysis is a promising strategy to address waste management and reduce CO 2 emissions. However, the economic implication of retrofitting a combined heat and power plant into oxy-fuel should be compared to its conventional air-fired strategy to enhance investments for carbon capture strategies. This paper investigates the integration of a waste-to-energy combined heat and power plant with an alkaline electrolyzer for oxy-fuel combustion and its economic competitiveness against the non-retrofitted air-fired combined heat and power plant. An air-fired power plant and its retrofitting into oxy-fuel combustion were modeled using AspenPlus based on the data from a real power plant (250 MW th ), situated in Finland. Retrofitting the chosen air-fired power plant required additional electric power of 320 MW el , supplemented by the grid, to satisfy the demand of the electrolyzer (372 MW). Nevertheless, the implementation of oxy-fuel combustion and waste heat recovery from the electrolyzer increased the district heating output from 154 to 350 MW th . Owing to a sensitivity analysis, it was found that the optimal exploitation of the thermal energy in the flue gas was achieved with a recirculation fraction of 70 %–80 % (70.5 % in this study). The oxy-fuel system produced a mass flow rate of CO 2 equal to 18.4 kg/s with a purity of 99.2 mol% and 2.06 kg/s of pure H 2 with a molar ratio of 2.5:1 (H 2 –CO 2 ). The price of H 2 , produced by the oxy-fuel retrofitted system, to obtain the same profit as the conventional air-fired combined and heat power plant was 1.57 EUR/kg. Due to its economic competitiveness, the proposed retrofitting into oxy-fuel combustion can be implemented on large scale, thus making a significant impact on reducing CO 2 emissions. • Retrofitting into oxy-fuel combustion (250 MW th ) required an electrolyzer with a capacity of 372 MW. • Waste heat recovery from electrolysis increased the district heating output by 126 %. • The system produced H 2 and CO 2 with mass flow rates of 2.1 and 18.4 kg/s, respectively. • The oxy-fuel system has the same profit as the air-fired one if H 2 is sold at 1.57 EUR/kg.

FuelVol. 398
Ghent University (BE), Aalto University (FI)
KAUTE-Säätiö, Aalto-Yliopisto, Tekniikan Edistämissäätiö
Openalex Percentile: Top 6%
Hybrid Renewable Energy Systems
4.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.