Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures

The aim of this study was to determine the efficacy of different protocols of cone beam computed tomography units with image resolutions for identifying dental root fractures. Accordingly, 24 single-rooted teeth were endodontically prepared using gutta-percha, fibreglass, or metal. Root fractures were caused in 50% of the samples. The teeth were included in a dry jaw and scanned using two tomographic units: OP300 and 3D Veraview. These tomographs respectively achieved an accuracy of 0.88 and 0.83 and a sensitivity of 0.78 and 0.83. The OP300 Maxio device had a high specificity of 0.98 compared to the 3D Veraview's 0.83. Thus, the two devices tested were both adequate for the identification of root fractures. However, the 3D Veraview demonstrated greater accuracy in the detection of root fractures in roots containing metal posts, while the OP300 showed greater accuracy with the use of fibreglass posts. The presence of gutta-percha compromised the identification of fractures with both devices.

Authors

Institutions

Publication Details

Journal
Australian Endodontic Journal
Published
2025-05-03
DOI
https://doi.org/10.1111/aej.12945
Citations
1
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
1.79
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures

J. E. Zorzi, Thiago de Oliveira Gamba, C. A. Perottoni, Eduardo Thomazi et al.
1 citations
Australian Endodontic Journal
Dental Radiography and Imaging
1.79
article

Influence of Different Protocols of Cone‐Beam Computed Tomography Units of High and Low Resolution on the Identification of Root Fractures

J. E. Zorzi, Thiago de Oliveira Gamba, C. A. Perottoni, Eduardo Thomazi, Janaína Guzzo Zechin, Érica Pozo Mautone, Rodrigo Torriani
article en
1 citations

Abstract

The aim of this study was to determine the efficacy of different protocols of cone beam computed tomography units with image resolutions for identifying dental root fractures. Accordingly, 24 single-rooted teeth were endodontically prepared using gutta-percha, fibreglass, or metal. Root fractures were caused in 50% of the samples. The teeth were included in a dry jaw and scanned using two tomographic units: OP300 and 3D Veraview. These tomographs respectively achieved an accuracy of 0.88 and 0.83 and a sensitivity of 0.78 and 0.83. The OP300 Maxio device had a high specificity of 0.98 compared to the 3D Veraview's 0.83. Thus, the two devices tested were both adequate for the identification of root fractures. However, the 3D Veraview demonstrated greater accuracy in the detection of root fractures in roots containing metal posts, while the OP300 showed greater accuracy with the use of fibreglass posts. The presence of gutta-percha compromised the identification of fractures with both devices.

Australian Endodontic JournalVol. 51(2)
Universidade Federal do Rio Grande do Sul (BR), Universidade de Caxias do Sul (BR), Instituto Federal Farroupilha (BR)
Openalex Percentile: Top 17%
Dental Radiography and Imaging
1.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.