Influences of impulse generators on the impulse characteristics of grounding systems

It is important to ensure the effectiveness of the experimental test set up and to accurately characterize grounding systems under high impulse conditions, the study on the effect of impulse generator is therefore needed. As with other experimental work, the test results may be influenced not only by the characteristics of the test load under study, but also the test arrangement, rating of the impulse generator and transducers. In this work, sources of this overshoot/spike observed in voltage and current traces of 1-rod, 3-rod, and 4-rod electrodes subjected to two impulse current generators of different rating: generating at maximum voltage and current of 100 kV, 1.5 kA, and 300 kV, 10 kA with the same response time of 1.2/50 μs are identified with the aid of simulation work.

Authors

Publication Details

Journal
Bulletin of Electrical Engineering and Informatics
Published
2025-05-02
DOI
https://doi.org/10.11591/eei.v14i3.8467
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influences of impulse generators on the impulse characteristics of grounding systems

Usman Muhammad, Fazlul Aman, Normiza Mohamad Nor, Miszaina Osman et al.
Bulletin of Electrical Engineering and Informatics
Vacuum and Plasma Arcs
article

Influences of impulse generators on the impulse characteristics of grounding systems

Usman Muhammad, Fazlul Aman, Normiza Mohamad Nor, Miszaina Osman, N. Ahmad
article en

Abstract

It is important to ensure the effectiveness of the experimental test set up and to accurately characterize grounding systems under high impulse conditions, the study on the effect of impulse generator is therefore needed. As with other experimental work, the test results may be influenced not only by the characteristics of the test load under study, but also the test arrangement, rating of the impulse generator and transducers. In this work, sources of this overshoot/spike observed in voltage and current traces of 1-rod, 3-rod, and 4-rod electrodes subjected to two impulse current generators of different rating: generating at maximum voltage and current of 100 kV, 1.5 kA, and 300 kV, 10 kA with the same response time of 1.2/50 μs are identified with the aid of simulation work.

Bulletin of Electrical Engineering and InformaticsVol. 14(3)
Openalex Percentile: Top 93%
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.