On-Ground Testing of Dual-Sided Release Mechanism of TianQin Test Mass Using a Pendulum

The high-precision gravitational reference sensor, which hosts a heavy test mass (TM) surrounded by electrodes with a relatively large gap, is crucial in all high-sensitivity drag-free sensors. Consequently, a dedicated locking mechanism is needed to securely hold the TM during the launch phase. After reaching the intended orbit, the TM is released to a free-falling state and subsequently captured by electrostatic actuation, which demands that the transferred momentum and angular momentum to the TM do not exceed 10-5kgm/s and 10-7kgm2/s, respectively. This paper introduces a three-level structural design of the locking-and-release mechanism. In order to investigate the release requirement, a pendulum system has been developed for on-ground testing. The mock-up of the TM is entirely consistent with the size and mass of TianQin TM, and the dual-sided release tips constrain the TM and then rapidly retract simultaneously, after which the transferred momentum and angular momentum are estimated from the free oscillations as 0.38(21)×10-5kgm/s and 0.15(14)×10-7kgm2/s with a preload force of 0.3 N. This proposes a feasible scheme for validating the release mechanism conducting impulse testing for the TianQin project.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-05-02
DOI
https://doi.org/10.3390/s25092878
Citations
6
Primary Topic
Pulsars and Gravitational Waves Research
Type
article
Field-Weighted Citation Impact
6.93

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-Ground Testing of Dual-Sided Release Mechanism of TianQin Test Mass Using a Pendulum

Wen-Hai Tan, Chao Xue, Ji Wang, Shan-Qing Yang et al.
6 citations
Sensors
Pulsars and Gravitational Waves Research
6.93
article

On-Ground Testing of Dual-Sided Release Mechanism of TianQin Test Mass Using a Pendulum

Wen-Hai Tan, Chao Xue, Ji Wang, Shan-Qing Yang, Zefan Zhou, Biao Yang, Jie Chang, Diwen Shi, Bing-Wei Cai
article en
6 citations

Abstract

The high-precision gravitational reference sensor, which hosts a heavy test mass (TM) surrounded by electrodes with a relatively large gap, is crucial in all high-sensitivity drag-free sensors. Consequently, a dedicated locking mechanism is needed to securely hold the TM during the launch phase. After reaching the intended orbit, the TM is released to a free-falling state and subsequently captured by electrostatic actuation, which demands that the transferred momentum and angular momentum to the TM do not exceed 10-5kgm/s and 10-7kgm2/s, respectively. This paper introduces a three-level structural design of the locking-and-release mechanism. In order to investigate the release requirement, a pendulum system has been developed for on-ground testing. The mock-up of the TM is entirely consistent with the size and mass of TianQin TM, and the dual-sided release tips constrain the TM and then rapidly retract simultaneously, after which the transferred momentum and angular momentum are estimated from the free oscillations as 0.38(21)×10-5kgm/s and 0.15(14)×10-7kgm2/s with a preload force of 0.3 N. This proposes a feasible scheme for validating the release mechanism conducting impulse testing for the TianQin project.

SensorsVol. 25(9)
Sun Yat-sen University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China, Basic and Applied Basic Research Foundation of Guangdong Province
Affordable and clean energy
Openalex Percentile: Top 3%
Pulsars and Gravitational Waves Research
6.93
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On-Ground Testing of Dual-Sided Release Mechanism of TianQin Test Mass Using a Pendulum — Wen-Hai Tan, Chao Xue, et al. · Sensors (2025) | TGRS Research Map | TGRS