Critical Wind Direction Angles and Edge Module Vulnerability in Fixed Double-Row Photovoltaic (PV) Arrays: Analysis of Extreme Wind Conditions Based on CFD Simulation

Fixed double-row photovoltaic (PV) arrays are susceptible to wind-induced damage, while their wind load characteristics remain inadequately investigated. This study employs computational fluid dynamics (CFD) simulations to systematically analyze wind load behavior under varying operational conditions, aiming to identify critical scenarios and structural vulnerabilities. First, the validity of the CFD methodology was verified through direct comparison between wind tunnel pressure measurements of an isolated PV module and corresponding numerical simulations. Subsequently, scaled PV array models were constructed to replicate practical engineering configurations, enabling a systematic evaluation of wind direction effects on mean net wind pressure coefficients and three-component force coefficients. Finally, surface wind pressure distribution patterns were examined for four representative wind angles (0°, 45°, 135°, 180°). Results demonstrate that edge-positioned modules exhibit maximum mean net wind pressure coefficients and three-component force coefficients under oblique wind angles (45° and 135°), which are identified as the most critical operational conditions. In contrast, minimal wind loads were observed at a 90° wind angle, indicating an optimal orientation for array installation. Additionally, significantly higher surface wind pressure coefficients were recorded for edge modules under oblique winds (45°/135°) compared to both interior modules and other wind angles. It was found through the study that under upwind conditions (0–90°), the lower-row components are capable of withstanding greater wind loads, whereas under downwind conditions (90–180°), an increase in the loads exerted on the upper-row components was observed.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-05-02
DOI
https://doi.org/10.3390/en18092330
Citations
1
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Critical Wind Direction Angles and Edge Module Vulnerability in Fixed Double-Row Photovoltaic (PV) Arrays: Analysis of Extreme Wind Conditions Based on CFD Simulation

Yupeng Zhou, Hongzhou Zhang, Zhenwei Luo, Yuheng Hu et al.
1 citations
Energies
Photovoltaic System Optimization Techniques
0.36
article

Critical Wind Direction Angles and Edge Module Vulnerability in Fixed Double-Row Photovoltaic (PV) Arrays: Analysis of Extreme Wind Conditions Based on CFD Simulation

Yupeng Zhou, Hongzhou Zhang, Zhenwei Luo, Yuheng Hu, Yuan Guo-shun
article en
1 citations

Abstract

Fixed double-row photovoltaic (PV) arrays are susceptible to wind-induced damage, while their wind load characteristics remain inadequately investigated. This study employs computational fluid dynamics (CFD) simulations to systematically analyze wind load behavior under varying operational conditions, aiming to identify critical scenarios and structural vulnerabilities. First, the validity of the CFD methodology was verified through direct comparison between wind tunnel pressure measurements of an isolated PV module and corresponding numerical simulations. Subsequently, scaled PV array models were constructed to replicate practical engineering configurations, enabling a systematic evaluation of wind direction effects on mean net wind pressure coefficients and three-component force coefficients. Finally, surface wind pressure distribution patterns were examined for four representative wind angles (0°, 45°, 135°, 180°). Results demonstrate that edge-positioned modules exhibit maximum mean net wind pressure coefficients and three-component force coefficients under oblique wind angles (45° and 135°), which are identified as the most critical operational conditions. In contrast, minimal wind loads were observed at a 90° wind angle, indicating an optimal orientation for array installation. Additionally, significantly higher surface wind pressure coefficients were recorded for edge modules under oblique winds (45°/135°) compared to both interior modules and other wind angles. It was found through the study that under upwind conditions (0–90°), the lower-row components are capable of withstanding greater wind loads, whereas under downwind conditions (90–180°), an increase in the loads exerted on the upper-row components was observed.

EnergiesVol. 18(9)
Xinjiang Production and Construction Corps (CN), Tarim University (CN)
Openalex Percentile: Top 44%
Photovoltaic System Optimization Techniques
0.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.