Simulation of Heat Pump with Heat Storage and PV System—Increase in Self-Consumption in a Polish Household

The use of renewables in heat production requires methods to overcome the issue of asynchronous heat load and energy production. The most effective method for analyzing the intricate thermal dynamics of an existing building is through transient simulation, utilizing real-world weather data. This approach offers a far more nuanced understanding than static calculations, which often fail to capture the dynamic interplay of environmental factors and building performance. Transient simulations, by their nature, model the building’s thermal behavior over time, reflecting the continuous fluctuations in temperature, solar radiation, and wind speed. Leveraging actual meteorological data enables the simulation model to faithfully capture system dynamics under realistic operational scenarios. This is crucial for evaluating the effectiveness of heating, ventilation, and air conditioning (HVAC) systems, identifying potential energy inefficiencies, and assessing the impact of various energy-saving measures. The simulation can reveal how the building’s thermal mass absorbs and releases heat, how solar gains influence indoor temperatures, and how ventilation patterns affect heat losses. In this paper, a household heating system consisting of an air source heat pump, PV, and buffer tank is simulated and analyzed. The 3D model accurately represents the building’s geometry and thermal properties. This virtual representation serves as the basis for calculating heat losses and gains, considering factors such as insulation levels, window characteristics, and building orientation. The approach is based on the calculation of building heat load based on a 3D model and EN ISO 52016-1 standard. The heat load is modeled based on air temperature and sun irradiance. The heating system is modeled in EBSILON professional 16.00 software for the calculation of transient 10 min time step heat production during the heating season. The results prove that a buffer tank with the right heat production control system can efficiently increase the auto consumption of self-produced PV electric energy, leading to a reduction in environmental effects and higher economic profitability.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-05-02
DOI
https://doi.org/10.3390/en18092325
Citations
7
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
7.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of Heat Pump with Heat Storage and PV System—Increase in Self-Consumption in a Polish Household

Piotr Michalak, Jakub Szymiczek, Krzysztof Szczotka
7 citations
Energies
Building Energy and Comfort Optimization
7.04
article

Simulation of Heat Pump with Heat Storage and PV System—Increase in Self-Consumption in a Polish Household

Piotr Michalak, Jakub Szymiczek, Krzysztof Szczotka
article en
7 citations

Abstract

The use of renewables in heat production requires methods to overcome the issue of asynchronous heat load and energy production. The most effective method for analyzing the intricate thermal dynamics of an existing building is through transient simulation, utilizing real-world weather data. This approach offers a far more nuanced understanding than static calculations, which often fail to capture the dynamic interplay of environmental factors and building performance. Transient simulations, by their nature, model the building’s thermal behavior over time, reflecting the continuous fluctuations in temperature, solar radiation, and wind speed. Leveraging actual meteorological data enables the simulation model to faithfully capture system dynamics under realistic operational scenarios. This is crucial for evaluating the effectiveness of heating, ventilation, and air conditioning (HVAC) systems, identifying potential energy inefficiencies, and assessing the impact of various energy-saving measures. The simulation can reveal how the building’s thermal mass absorbs and releases heat, how solar gains influence indoor temperatures, and how ventilation patterns affect heat losses. In this paper, a household heating system consisting of an air source heat pump, PV, and buffer tank is simulated and analyzed. The 3D model accurately represents the building’s geometry and thermal properties. This virtual representation serves as the basis for calculating heat losses and gains, considering factors such as insulation levels, window characteristics, and building orientation. The approach is based on the calculation of building heat load based on a 3D model and EN ISO 52016-1 standard. The heat load is modeled based on air temperature and sun irradiance. The heating system is modeled in EBSILON professional 16.00 software for the calculation of transient 10 min time step heat production during the heating season. The results prove that a buffer tank with the right heat production control system can efficiently increase the auto consumption of self-produced PV electric energy, leading to a reduction in environmental effects and higher economic profitability.

EnergiesVol. 18(9)
AGH University of Krakow (PL)
Akademia Górniczo-Hutnicza im. Stanislawa Staszica
Openalex Percentile: Top 3%
Building Energy and Comfort Optimization
7.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.