A computational model for complete separation of circulating tumor cells inside grooved microchannel under the effect of dielectrophoretic forces

Understanding the separation of particles inside a microchannel offers greater insights into several crucial issues, such as the separation of circulating tumor cells (CTCs) for early cancer detection and the separation of red blood cells (RBCs) and white blood cells (WBCs) from blood samples. Various microfluidic devices have been developed to successfully separate cancer cells from blood samples under the effect of various forces. These forces include hydrodynamic forces, electric forces, magnetic forces, and acoustic forces. However, complete separation efficiency has not yet been achieved with these devices. Thus, attempts were made to conduct a simulation study to completely separate CTCs from RBCs, WBCs, and platelets in a grooved microchannel. Particle tracing in a laminar flow module was employed to model the flow of WBCs, RBCs, platelets, and CTCs in a Newtonian medium. A separation efficiency of 100% for CTCs was achieved under the effect of dielectrophoretic forces inside the grooved channel. Studies were also conducted to discern that separation efficiency significantly reduces in the non-grooved channel. In addition, a maximum transmissivity of 98% was also reported for CTCs. It was reported that separation efficiency is maximum with eight flat-shaped electrodes in a grooved microchannel operating under a voltage range of 6–7 V. The simulation results will be extended to fabricate a grooved microchannel that can completely separate CTCs from blood samples. Furthermore, the study also revealed the significance of dielectrophoretic forces in separating particles of different sizes.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-05-01
DOI
https://doi.org/10.1063/5.0267085
Citations
2
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A computational model for complete separation of circulating tumor cells inside grooved microchannel under the effect of dielectrophoretic forces

Siddhartha Sankar Ghosh, Amaresh Dalal, Niraj Kr Prasad, Anupam Neogi
2 citations
Physics of Fluids
Microfluidic and Bio-sensing Technologies
1.35
article

A computational model for complete separation of circulating tumor cells inside grooved microchannel under the effect of dielectrophoretic forces

Siddhartha Sankar Ghosh, Amaresh Dalal, Niraj Kr Prasad, Anupam Neogi
article en
2 citations

Abstract

Understanding the separation of particles inside a microchannel offers greater insights into several crucial issues, such as the separation of circulating tumor cells (CTCs) for early cancer detection and the separation of red blood cells (RBCs) and white blood cells (WBCs) from blood samples. Various microfluidic devices have been developed to successfully separate cancer cells from blood samples under the effect of various forces. These forces include hydrodynamic forces, electric forces, magnetic forces, and acoustic forces. However, complete separation efficiency has not yet been achieved with these devices. Thus, attempts were made to conduct a simulation study to completely separate CTCs from RBCs, WBCs, and platelets in a grooved microchannel. Particle tracing in a laminar flow module was employed to model the flow of WBCs, RBCs, platelets, and CTCs in a Newtonian medium. A separation efficiency of 100% for CTCs was achieved under the effect of dielectrophoretic forces inside the grooved channel. Studies were also conducted to discern that separation efficiency significantly reduces in the non-grooved channel. In addition, a maximum transmissivity of 98% was also reported for CTCs. It was reported that separation efficiency is maximum with eight flat-shaped electrodes in a grooved microchannel operating under a voltage range of 6–7 V. The simulation results will be extended to fabricate a grooved microchannel that can completely separate CTCs from blood samples. Furthermore, the study also revealed the significance of dielectrophoretic forces in separating particles of different sizes.

Physics of FluidsVol. 37(5)
Indian Institute of Technology Guwahati (IN)
Openalex Percentile: Top 20%
Microfluidic and Bio-sensing Technologies
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A computational model for complete separation of circulating tumor cells inside grooved microchannel under the effect of dielectrophoretic forces — Siddhartha Sankar Ghosh, Amaresh Dalal, et al. · Physics of Fluids (2025) | TGRS Research Map | TGRS