Testing commonly used background removal procedures for XPS quantitation of homogeneous material: Fe2O3, a transition metal oxide example

We have examined, for Fe2O3, the three commonly used background removal procedures: Shirley (iterated), S; Tougaard (a modified U2 version), T; and Linear, L, for the Fe2p and O1s spectra. The high BE end point, which is where it is assumed that there is no further intrinsic signal contribution, is most important. It is quite easy, but arbitrary, to adjust the Fe2p and O1s end points to return an “expected” answer for Fe2O3, 40% atomic Fe, while assuming 100% accuracy for cross sections and for inelastic mean free path length parameters for Fe2p and O1s. This further assumes (a) that the transmission function of the instrument is accurate and (b) that O1s intensity from surface OH is accounted for correctly. We determine the variation in the composition with the variation in the end point used. Ideally, one should include all observable substructures, while keeping the eV range similar for Fe2p and O1s. T and S then give quite similar compositions, despite the fact that T removes far less intensity. The reason is clear. The scattered electron backgrounds are proportional to the photoemission signals generating them, so provided the same procedure over the same eV range is used for both Fe2p and O1s, the functional form of the subtraction is of lesser importance. Owing to this, it may even be acceptable to use a method ratioing total intensities, signal plus background. Absolute compositional accuracy is not the primary subject of this paper, but we do address this in the discussion.

Authors

Institutions

Publication Details

Journal
Journal of Vacuum Science & Technology A Vacuum Surfaces and Films
Published
2025-05-01
DOI
https://doi.org/10.1116/6.0004533
Citations
3
Primary Topic
Electron and X-Ray Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
1.98
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Testing commonly used background removal procedures for XPS quantitation of homogeneous material: Fe2O3, a transition metal oxide example

Paul S. Bagus, B. Vincent Crist, C. R. Brundle
3 citations
Journal of Vacuum Science & Technology A Vacuum Surfaces and Films
Electron and X-Ray Spectroscopy Techniques
1.98
article

Testing commonly used background removal procedures for XPS quantitation of homogeneous material: Fe2O3, a transition metal oxide example

Paul S. Bagus, B. Vincent Crist, C. R. Brundle
article en
3 citations

Abstract

We have examined, for Fe2O3, the three commonly used background removal procedures: Shirley (iterated), S; Tougaard (a modified U2 version), T; and Linear, L, for the Fe2p and O1s spectra. The high BE end point, which is where it is assumed that there is no further intrinsic signal contribution, is most important. It is quite easy, but arbitrary, to adjust the Fe2p and O1s end points to return an “expected” answer for Fe2O3, 40% atomic Fe, while assuming 100% accuracy for cross sections and for inelastic mean free path length parameters for Fe2p and O1s. This further assumes (a) that the transmission function of the instrument is accurate and (b) that O1s intensity from surface OH is accounted for correctly. We determine the variation in the composition with the variation in the end point used. Ideally, one should include all observable substructures, while keeping the eV range similar for Fe2p and O1s. T and S then give quite similar compositions, despite the fact that T removes far less intensity. The reason is clear. The scattered electron backgrounds are proportional to the photoemission signals generating them, so provided the same procedure over the same eV range is used for both Fe2p and O1s, the functional form of the subtraction is of lesser importance. Owing to this, it may even be acceptable to use a method ratioing total intensities, signal plus background. Absolute compositional accuracy is not the primary subject of this paper, but we do address this in the discussion.

Journal of Vacuum Science & Technology A Vacuum Surfaces and FilmsVol. 43(3)
University of North Texas (US), Oregon Physics (United States) (US)
Openalex Percentile: Top 15%
Electron and X-Ray Spectroscopy Techniques
1.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.