A Statistical Approach to Assess Biological Equivalent Mean Organ Dose (MOD) for Different Fractionations in Thoracic Radiotherapy
<b>Background:</b> With advances in radiotherapy technology, there are more technological options and fractionation regiments for different stages of lung cancer. Evaluation of the possibility of severe organ toxicity for the organ-at-risks (OARs) is often required when treating patients with unusual fractionations or combining two treatment plans with different fractionations. <b>Purpose:</b> This study aims to provide an approach that can reasonably estimate the possibility of toxicity using a biological equivalent mean organ dose (MOD)-based model from the 2 Gy per fraction era for various fractionations. <b>Methods and Materials:</b> The dose volume histograms (DVHs) of 272 patients treated with radiotherapy for lung cancer at a prescribed dose of 2 Gy × 30 f were used for analysis. For each patient, we calculated the biological equivalent MOD based on a dose conversion of EQD2 (equivalent to a dose of 2 Gy/fraction to the organ), the MOD based on the physical dose, and the d-value that makes the biological equivalent MOD based on a dose conversion of EQDd equal to the physical MOD. Statistical analysis was then performed to determine the relationship of the d-value to the corresponding physical MOD in percentage dose (relative MOD). <b>Results:</b> Equivalent MODs based on EQD2 were smaller than the physical MOD for each patient, suggesting that using EQD2 conversion would underestimate the equivalent MOD. The distribution of d-values with physical relative mean lung dose (RMLD) showed a normal peak with an average of d = 1.3 Gy, suggesting that the equivalent MLD can be estimated using EQD1.3 for various fractionations. Regression analysis showed that the d-value could be estimated as d = 0.93+3.0×RMLD, d = 0.044+5.8×RMED, and d = 4.7×RMHD for the lung, esophagus, and heart, respectively, suggesting that the equivalent MLD, MED, and MHD can be estimated using EQDd. <b>Conclusions:</b> Using EQD2 conversion underestimates the equivalent MOD, and the equivalent MOD converted by EQDd with an appropriate d-value may enhance the assessment of organ toxicity.
Authors
- Guangshan Wang
- Xiaohang Qin
- Feng‐Ming Kong (ORCID: https://orcid.org/0000-0003-2652-098X)
- Bin Sun (ORCID: https://orcid.org/0000-0002-7492-1473)
- Yuyan Gao (ORCID: https://orcid.org/0000-0003-4765-4477)
- Yinghui Li (ORCID: https://orcid.org/0000-0002-7596-9508)
- Jian-Yue Jin
- Siyao Zhong
Institutions
- Capital Medical University (CN)
- Beijing Chest Hospital (CN)
- Beijing Luhe Hospital Affiliated to Capital Medical University (CN)
- University of Hong Kong - Shenzhen Hospital (CN)
- University of Hong Kong (HK)
Publication Details
- Journal
- Biomedicines
- Published
- 2025-05-02
- DOI
- https://doi.org/10.3390/biomedicines13051110
- Citations
- 2
- Primary Topic
- Lung Cancer Diagnosis and Treatment
- Type
- article
- Field-Weighted Citation Impact
- 3.04