Determination of Fluconazole in Children in Small Blood Volumes Using Volumetric Absorptive Microsampling (VAMS) and Isocratic High-Performance Liquid Chromatography–Ultraviolet (HPLC–UV) Detection

<b>Objectives</b>: A simple method for quantifying fluconazole in small blood volumes has been developed using volumetric absorptive microsampling (VAMS<sup>®</sup>) technology and isocratic high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection. <b>Methods</b>: For sample collection, Mitra<sup>®</sup> devices are used to keep the sample volume at 10 µL. For the quantitative determination of fluconazole, the Mitra<sup>®</sup> samples are extracted using acetonitrile as the extraction agent, containing 2-(4-chlorophenyl)-1,3-bis(1,2,4-triazol-1-yl)propan-2-ol as the internal standard. A Synergi 4 μm Polar-RP 80 Å (150 × 2 mm) column forms the stationary phase, and a mixture of acetonitrile and phosphate buffer is the mobile phase. The UV detection is set at a wavelength of 210 nm. The therapeutic concentration range of 5 to 160 mg/L is covered, and the linear equation with 1/x<sup>2</sup> weighting is used to determine unknown samples. This method has been validated according to the current EMA and FDA guidelines for bioanalytical methods. <b>Results</b>: The validation data obtained after analysing whole blood samples (EDTA) showed within- and between-run accuracy between 94.4% and 115% and precision between 0.4% and 9.4%, respectively. A lower limit of quantification (LLOQ) of 5 mg/L was sufficient for therapeutic drug monitoring in paediatric patients receiving fluconazole as antifungal prophylaxis after haematopoietic cell transplantation. <b>Conclusions</b>: So far, 211 samples from 49 patients were successfully analysed, and concentrations between 5.84 mg/L and 107 mg/L were determined for whole blood Mitra<sup>®</sup> samples. To our knowledge, this is the first application of VAMS<sup>®</sup> technology using simple and cheap HPLC-UV quantification.

Authors

Institutions

Publication Details

Journal
Pharmaceutics
Published
2025-05-01
DOI
https://doi.org/10.3390/pharmaceutics17050592
Citations
1
Primary Topic
Antifungal resistance and susceptibility
Type
article
Field-Weighted Citation Impact
1.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Fluconazole in Children in Small Blood Volumes Using Volumetric Absorptive Microsampling (VAMS) and Isocratic High-Performance Liquid Chromatography–Ultraviolet (HPLC–UV) Detection

Andreas H. Groll, Georg Hempel, Franziska Zimbelmann
1 citations
Pharmaceutics
Antifungal resistance and susceptibility
1.40
article

Determination of Fluconazole in Children in Small Blood Volumes Using Volumetric Absorptive Microsampling (VAMS) and Isocratic High-Performance Liquid Chromatography–Ultraviolet (HPLC–UV) Detection

Andreas H. Groll, Georg Hempel, Franziska Zimbelmann
article en
1 citations

Abstract

<b>Objectives</b>: A simple method for quantifying fluconazole in small blood volumes has been developed using volumetric absorptive microsampling (VAMS<sup>®</sup>) technology and isocratic high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection. <b>Methods</b>: For sample collection, Mitra<sup>®</sup> devices are used to keep the sample volume at 10 µL. For the quantitative determination of fluconazole, the Mitra<sup>®</sup> samples are extracted using acetonitrile as the extraction agent, containing 2-(4-chlorophenyl)-1,3-bis(1,2,4-triazol-1-yl)propan-2-ol as the internal standard. A Synergi 4 μm Polar-RP 80 Å (150 × 2 mm) column forms the stationary phase, and a mixture of acetonitrile and phosphate buffer is the mobile phase. The UV detection is set at a wavelength of 210 nm. The therapeutic concentration range of 5 to 160 mg/L is covered, and the linear equation with 1/x<sup>2</sup> weighting is used to determine unknown samples. This method has been validated according to the current EMA and FDA guidelines for bioanalytical methods. <b>Results</b>: The validation data obtained after analysing whole blood samples (EDTA) showed within- and between-run accuracy between 94.4% and 115% and precision between 0.4% and 9.4%, respectively. A lower limit of quantification (LLOQ) of 5 mg/L was sufficient for therapeutic drug monitoring in paediatric patients receiving fluconazole as antifungal prophylaxis after haematopoietic cell transplantation. <b>Conclusions</b>: So far, 211 samples from 49 patients were successfully analysed, and concentrations between 5.84 mg/L and 107 mg/L were determined for whole blood Mitra<sup>®</sup> samples. To our knowledge, this is the first application of VAMS<sup>®</sup> technology using simple and cheap HPLC-UV quantification.

PharmaceuticsVol. 17(5)
University of Münster (DE), University Hospital Münster (DE)
Openalex Percentile: Top 21%
Antifungal resistance and susceptibility
1.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.