Utilizing Artificial Neural Networks to Correlate Energy Consumption and Intensity in Metal Industries for the Midwest States

Energy optimization and analysis are significant in mapping energy consumption and savings for various industries. This study sheds light on utilizing two main energy evaluation parameters: Energy Intensity Utilization (EIU) and Specific energy consumption (SEC). This research paper is founded on an extensive 10-year study, from 2013 to 2023, on more than 196 on-site energy assessments performed on various manufacturing companies in Wisconsin and Northern Illinois. This research is considered a comparative study, which aims to explore the correlation between those two parameters using linear regression analysis using SPSS (Statistical Package for Social Sciences) and validate the outcomes using Artificial Neural Networks (ANN). Besides, it is also employed to assess the most updated methods, procedures, and technological applications that are meant to increase energy efficiency. This study demonstrates the relationship between energy consumption, energy savings, and the effects of energy assessment across several industrial sectors. The results have shown a linear correlation between the EIU and SEC as two of the most significant parameters in measuring energy footprint in the energy-auditing sector. Also, the results have shown that the Annual Energy Savings Percentage (AES%) could have interdependence with both the SEC and EIU energy evaluation parameters, which could provide an energy footprint baseline for any stakeholder interested in penetrating the fabricated metal products industry. The ANN results have shown that underfitting occurs when the data model cannot accurately capture the relationship between the input and output variables. The reasons for the underfitting are that the data points are small (95 data points) for a neural network, and the complexity of the model is simplistic for a machine learning application.

Authors

Institutions

Publication Details

Journal
Spectrum of Mechanical Engineering and Operational Research.
Published
2025-05-02
DOI
https://doi.org/10.31181/smeor21202541
Primary Topic
Energy Efficiency and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilizing Artificial Neural Networks to Correlate Energy Consumption and Intensity in Metal Industries for the Midwest States

Yazeed AbuShanab, Ryoichi Samuel Amano, Mohamed Youssef, Kada Kada et al.
Spectrum of Mechanical Engineering and Operational Research.
Energy Efficiency and Management
article

Utilizing Artificial Neural Networks to Correlate Energy Consumption and Intensity in Metal Industries for the Midwest States

Yazeed AbuShanab, Ryoichi Samuel Amano, Mohamed Youssef, Kada Kada, Qais Alnawafah, Asma Khasawneh
article en

Abstract

Energy optimization and analysis are significant in mapping energy consumption and savings for various industries. This study sheds light on utilizing two main energy evaluation parameters: Energy Intensity Utilization (EIU) and Specific energy consumption (SEC). This research paper is founded on an extensive 10-year study, from 2013 to 2023, on more than 196 on-site energy assessments performed on various manufacturing companies in Wisconsin and Northern Illinois. This research is considered a comparative study, which aims to explore the correlation between those two parameters using linear regression analysis using SPSS (Statistical Package for Social Sciences) and validate the outcomes using Artificial Neural Networks (ANN). Besides, it is also employed to assess the most updated methods, procedures, and technological applications that are meant to increase energy efficiency. This study demonstrates the relationship between energy consumption, energy savings, and the effects of energy assessment across several industrial sectors. The results have shown a linear correlation between the EIU and SEC as two of the most significant parameters in measuring energy footprint in the energy-auditing sector. Also, the results have shown that the Annual Energy Savings Percentage (AES%) could have interdependence with both the SEC and EIU energy evaluation parameters, which could provide an energy footprint baseline for any stakeholder interested in penetrating the fabricated metal products industry. The ANN results have shown that underfitting occurs when the data model cannot accurately capture the relationship between the input and output variables. The reasons for the underfitting are that the data points are small (95 data points) for a neural network, and the complexity of the model is simplistic for a machine learning application.

Spectrum of Mechanical Engineering and Operational Research.Vol. 2(1)
University of Wisconsin–Milwaukee (US)
U.S. Department of Energy
Openalex Percentile: Top 95%
Energy Efficiency and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.