Calibration of the Induction Heating System for Dynamic Compression Test

Abstract The study focuses on calibrating a system for inductive heating of samples before performing dynamic compression tests using a Split Hopkinson Pressure Bar (SHPB). In the proposed set-up, the crucial role is played by the pyrometer, which could continuously control the temperature of the specimen during the test. The coupling of the experimental test together with numerical simulations (including thermal and mechanical simulations) is performed to calibrate the considered system. The key outcomes of the coupled experiment and simulation analyses are the shortest heating time required to achieve a uniform temperature in the neck of the sample and the change in the temperature field during cooling (after the heating ends). This procedure will also be used in real experiments to predict the temperature sensitivity of the material under dynamic compression under precisely controlled thermal conditions for a temperature range of 250 °C to 730 °C.

Authors

Institutions

Publication Details

Journal
Experimental Techniques
Published
2025-05-02
DOI
https://doi.org/10.1007/s40799-025-00807-3
Citations
3
Primary Topic
Metal Alloys Wear and Properties
Type
article
Field-Weighted Citation Impact
1.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of the Induction Heating System for Dynamic Compression Test

Wojciech Szymkuć, Vladimír Mózer, Michał Malendowski, Kamila Cábová et al.
3 citations
Experimental Techniques
Metal Alloys Wear and Properties
1.55
article

Calibration of the Induction Heating System for Dynamic Compression Test

Wojciech Szymkuć, Vladimír Mózer, Michał Malendowski, Kamila Cábová, Tomasz Jankowiak, František Wald, Jakub Šejna
article en
3 citations

Abstract

Abstract The study focuses on calibrating a system for inductive heating of samples before performing dynamic compression tests using a Split Hopkinson Pressure Bar (SHPB). In the proposed set-up, the crucial role is played by the pyrometer, which could continuously control the temperature of the specimen during the test. The coupling of the experimental test together with numerical simulations (including thermal and mechanical simulations) is performed to calibrate the considered system. The key outcomes of the coupled experiment and simulation analyses are the shortest heating time required to achieve a uniform temperature in the neck of the sample and the change in the temperature field during cooling (after the heating ends). This procedure will also be used in real experiments to predict the temperature sensitivity of the material under dynamic compression under precisely controlled thermal conditions for a temperature range of 250 °C to 730 °C.

Experimental TechniquesVol. 49(6)
Czech Technical University in Prague (CZ), Poznań University of Technology (PL)
Narodowym Centrum Nauki
Openalex Percentile: Top 18%
Metal Alloys Wear and Properties
1.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Calibration of the Induction Heating System for Dynamic Compression Test — Wojciech Szymkuć, Vladimír Mózer, et al. · Experimental Techniques (2025) | TGRS Research Map | TGRS