Development and validation of RP-HPLC method for the simultaneous determination of bempedoic acid and ezetimibe

A simple, rapid, precise, sensitive and reproducible reverse phase high performance liquid chromatography (RP-HPLC) method has been developed for the quantitative analysis of Bempedoic acid and Ezetimibe in pharmaceutical dosage form. Chromatographic separation of Bempedoic acid and Ezetimibe was achieved on Waters Alliance-e2695 by using Inertsil ODS (250x 4.6mm, 5µ) column and the mobile phase containing Methanol: 0.1% Perchloric acid in the ratio of 10:90% v/v. The flow rate was 1.0 ml/min; detection was carried out by absorption at 232nm using a photodiode array detector at ambient temperature. The number of theoretical plates and tailing factor for Bempedoic acid and Ezetimibe were NLT 2000 and should not more than 2 respectively. % Relative standard deviation of peak areas of all measurements always less than 2.0. The proposed method was validated according to ICH guidelines. The method was found to be simple, economical, suitable, precise, accurate & robust method for quantitative analysis of Bempedoic acid and Ezetimibe study of its stability.

Authors

Institutions

Publication Details

Journal
International Journal of Pharmaceutics and Drug Analysis
Published
2025-03-15
DOI
https://doi.org/10.47957/ijpda.v13i1.622
Primary Topic
Synthesis and biological activity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of RP-HPLC method for the simultaneous determination of bempedoic acid and ezetimibe

B Aruna, B Chaitanya, Hu A, M Divya et al.
International Journal of Pharmaceutics and Drug Analysis
Synthesis and biological activity
article

Development and validation of RP-HPLC method for the simultaneous determination of bempedoic acid and ezetimibe

B Aruna, B Chaitanya, Hu A, M Divya, Divya Sai Madaka
article en

Abstract

A simple, rapid, precise, sensitive and reproducible reverse phase high performance liquid chromatography (RP-HPLC) method has been developed for the quantitative analysis of Bempedoic acid and Ezetimibe in pharmaceutical dosage form. Chromatographic separation of Bempedoic acid and Ezetimibe was achieved on Waters Alliance-e2695 by using Inertsil ODS (250x 4.6mm, 5µ) column and the mobile phase containing Methanol: 0.1% Perchloric acid in the ratio of 10:90% v/v. The flow rate was 1.0 ml/min; detection was carried out by absorption at 232nm using a photodiode array detector at ambient temperature. The number of theoretical plates and tailing factor for Bempedoic acid and Ezetimibe were NLT 2000 and should not more than 2 respectively. % Relative standard deviation of peak areas of all measurements always less than 2.0. The proposed method was validated according to ICH guidelines. The method was found to be simple, economical, suitable, precise, accurate & robust method for quantitative analysis of Bempedoic acid and Ezetimibe study of its stability.

International Journal of Pharmaceutics and Drug Analysis
Institute of Philosophy (HU)
Openalex Percentile: Top 93%
Synthesis and biological activity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and validation of RP-HPLC method for the simultaneous determination of bempedoic acid and ezetimibe — B Aruna, B Chaitanya, et al. · International Journal of Pharmaceutics and Drug Analysis (2025) | TGRS Research Map | TGRS