Effectiveness of Self-Contained Breathing Apparatus: An Observational Study on Exposure to Polycyclic Aromatic Hydrocarbons and Associated Respiratory Risks

Background: An effective risk assessment and management methodology is essential to minimize/mitigate health risks associated with firefighting activities. The use of a self-contained breathing apparatus (SCBA) is mandatory during structure fires to protect firefighters from hazardous fire effluents, yet the protectiveness of the SCBA system has rarely been evaluated. Objective: This study characterizes, for the first time, the levels of 18 polycyclic aromatic hydrocarbons (PAHs) inside the SCBA facemask, during 7 structure-firefighting exercises and estimates associated respiratory risks. Methods: Cotton disk samples were collected via passive air sampling and analyzed using liquid chromatography with fluorescence and UV–Vis detection. Results: Levels of total PAHs (∑PAHs: 9.17–29.6 ng/m3) and ∑PAHscarcinogenic (0.41–5.73 ng/m3) were below the occupational limits defined by governmental agencies. The low-molecular-weight PAHs were predominant (79.5–91.4%), and the (possible/known) carcinogenic naphthalene (0.26–2.00 ng/m3), anthracene (0.088–0.31 ng/m3), chrysene (0.046–0.39 ng/m3), benzo(b+j)fluoranthene (0.18–0.40 ng/m3), and benzo(a)pyrene (0.041–0.18 ng/m3) were detected in all samples. The respiratory health risk analysis demonstrated negligible risks associated with the inhalation of PAHs. A health principal component analysis could identify firefighters at increased respiratory risk. Conclusions: The effectiveness of SCBA was demonstrated, reinforcing the need to ensure its correct use during all the phases of structure fires, including during overhaul.

Authors

Institutions

Publication Details

Journal
Fire
Published
2025-05-02
DOI
https://doi.org/10.3390/fire8050182
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effectiveness of Self-Contained Breathing Apparatus: An Observational Study on Exposure to Polycyclic Aromatic Hydrocarbons and Associated Respiratory Risks

Cristina Maria Delerue-Matos, Francisca Rodrigues, Alice Santos‐Silva, Marta Oliveira et al.
Fire
Indoor Air Quality and Microbial Exposure
article

Effectiveness of Self-Contained Breathing Apparatus: An Observational Study on Exposure to Polycyclic Aromatic Hydrocarbons and Associated Respiratory Risks

Cristina Maria Delerue-Matos, Francisca Rodrigues, Alice Santos‐Silva, Marta Oliveira, Joana Teixeira
article en

Abstract

Background: An effective risk assessment and management methodology is essential to minimize/mitigate health risks associated with firefighting activities. The use of a self-contained breathing apparatus (SCBA) is mandatory during structure fires to protect firefighters from hazardous fire effluents, yet the protectiveness of the SCBA system has rarely been evaluated. Objective: This study characterizes, for the first time, the levels of 18 polycyclic aromatic hydrocarbons (PAHs) inside the SCBA facemask, during 7 structure-firefighting exercises and estimates associated respiratory risks. Methods: Cotton disk samples were collected via passive air sampling and analyzed using liquid chromatography with fluorescence and UV–Vis detection. Results: Levels of total PAHs (∑PAHs: 9.17–29.6 ng/m3) and ∑PAHscarcinogenic (0.41–5.73 ng/m3) were below the occupational limits defined by governmental agencies. The low-molecular-weight PAHs were predominant (79.5–91.4%), and the (possible/known) carcinogenic naphthalene (0.26–2.00 ng/m3), anthracene (0.088–0.31 ng/m3), chrysene (0.046–0.39 ng/m3), benzo(b+j)fluoranthene (0.18–0.40 ng/m3), and benzo(a)pyrene (0.041–0.18 ng/m3) were detected in all samples. The respiratory health risk analysis demonstrated negligible risks associated with the inhalation of PAHs. A health principal component analysis could identify firefighters at increased respiratory risk. Conclusions: The effectiveness of SCBA was demonstrated, reinforcing the need to ensure its correct use during all the phases of structure fires, including during overhaul.

FireVol. 8(5)
Universidade do Porto (PT), Rede de Química e Tecnologia (PT), Polytechnic Institute of Porto (PT)
Ministério da Ciência, Tecnologia e Ensino Superior, Universidade do Porto, Fundação para a Ciência e a Tecnologia
Openalex Percentile: Top 88%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.