Knowledge And Awarnesss Among Undergraduate Dental Students About Non Invasive Portable Hemoglobin Concentration Monitoring System Using Optical Sensor For Anemia Disease

Anemia is a condition in which red blood cells are not able to carry adequate oxygen to the body’s tissues, and is widely found in nearly a quarter of the world population. The typical method to screen for the iron-deficiency anemia, which is the major anemia found in the world, is to implement a blood test called a complete blood count (CBC). Therefore, this research presents an alternative method using an optical technique to measure hemoglobin concentration, which is the common indicator for diagnosing anemia. The light absorbance of the oxyhemoglobin at the wavelength of 660 nm and the deoxyhemoglobin at the wavelength of 880 nm were measured using the MAX30100 sensor. These wavelengths of light are obtained from red and infrared (IR) LEDs. The concept is based on the different absorption coefficients of blood at different electromagnetic wavelengths. This fact is used to indirectly calculate the hemoglobin concentration of blood through the modified Beer–Lambert law. Moreover, the result has been further converted to absolute hemoglobin concentration using a calibration curve derived from the cyanmethemoglobin test, which is the regular method for hemoglobin determination. The experiment shows that an accuracy of 90.9% can be achieved by our proposed noninvasive method. Therefore, the noninvasive portable hemoglobin concentration monitoring by the optical sensor has an acceptable result when compared with the invasive method, with less pain and lower risk of infection, as well as shorter processing time.

Authors

Institutions

Publication Details

Journal
International Journal of Allied Medical Sciences and Clinical Research
Published
2025-04-07
DOI
https://doi.org/10.61096/ijamscr.v13.iss2.2025.123-127
Primary Topic
Scientific and Engineering Research Topics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Knowledge And Awarnesss Among Undergraduate Dental Students About Non Invasive Portable Hemoglobin Concentration Monitoring System Using Optical Sensor For Anemia Disease

TMadhavi Padma, Mani Karthik, V. SrujanKumar, S Singh et al.
International Journal of Allied Medical Sciences and Clinical Research
Scientific and Engineering Research Topics
article

Knowledge And Awarnesss Among Undergraduate Dental Students About Non Invasive Portable Hemoglobin Concentration Monitoring System Using Optical Sensor For Anemia Disease

TMadhavi Padma, Mani Karthik, V. SrujanKumar, S Singh, M Hamza, K.V.N.R. Pratap
article en

Abstract

Anemia is a condition in which red blood cells are not able to carry adequate oxygen to the body’s tissues, and is widely found in nearly a quarter of the world population. The typical method to screen for the iron-deficiency anemia, which is the major anemia found in the world, is to implement a blood test called a complete blood count (CBC). Therefore, this research presents an alternative method using an optical technique to measure hemoglobin concentration, which is the common indicator for diagnosing anemia. The light absorbance of the oxyhemoglobin at the wavelength of 660 nm and the deoxyhemoglobin at the wavelength of 880 nm were measured using the MAX30100 sensor. These wavelengths of light are obtained from red and infrared (IR) LEDs. The concept is based on the different absorption coefficients of blood at different electromagnetic wavelengths. This fact is used to indirectly calculate the hemoglobin concentration of blood through the modified Beer–Lambert law. Moreover, the result has been further converted to absolute hemoglobin concentration using a calibration curve derived from the cyanmethemoglobin test, which is the regular method for hemoglobin determination. The experiment shows that an accuracy of 90.9% can be achieved by our proposed noninvasive method. Therefore, the noninvasive portable hemoglobin concentration monitoring by the optical sensor has an acceptable result when compared with the invasive method, with less pain and lower risk of infection, as well as shorter processing time.

International Journal of Allied Medical Sciences and Clinical ResearchVol. 13(2)
Mamata Medical College (IN)
Openalex Percentile: Top 90%
Scientific and Engineering Research Topics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Knowledge And Awarnesss Among Undergraduate Dental Students About Non Invasive Portable Hemoglobin Concentration Monitoring System Using Optical Sensor For Anemia Disease — TMadhavi Padma, Mani Karthik, et al. · International Journal of Allied Medical Sciences and Clinical Research (2025) | TGRS Research Map | TGRS