Local Glucose Tolerance Test Needle With Measurement and Administration Flow Channels

ABSTRACT Assessment of impaired insulin secretion and insulin resistance is critical to determining the type of diabetes and planning optimal management and preventive strategies in clinical practice. To measure insulin resistance, a minimally invasive needle with measurement and administration flow channels for local glucose tolerance tests was fabricated. The administration flow channel has a hole on the tip end of the flow channel. The microperfusion flow channel starts from the root side of the needle, turns around at the needle‐tip end, and returns back to the root side of the needle. It has a perforated membrane on the surface of the area placed in the skin when inserted. Glucose is administrated through the flow channel, and glucose concentration of the skin is measured by microperfusion before and after administration. When the perfusate is perfused into the microperfusion flow channel, since the glucose concentration of the skin is higher than the perfusate, glucose contained in the skin's interstitial fluid moves into the flow channel through the perforated membrane by concentration diffusion, and the glucose can be collected. The needle's administration and glucose‐collecting functions were evaluated in the skin of mice.

Authors

Institutions

Publication Details

Journal
Electronics and Communications in Japan
Published
2025-05-02
DOI
https://doi.org/10.1002/ecj.12486
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Local Glucose Tolerance Test Needle With Measurement and Administration Flow Channels

Yoichi Haga, Noriko Tsuruoka
Electronics and Communications in Japan
Diabetes Management and Research
article

Local Glucose Tolerance Test Needle With Measurement and Administration Flow Channels

Yoichi Haga, Noriko Tsuruoka
article en

Abstract

ABSTRACT Assessment of impaired insulin secretion and insulin resistance is critical to determining the type of diabetes and planning optimal management and preventive strategies in clinical practice. To measure insulin resistance, a minimally invasive needle with measurement and administration flow channels for local glucose tolerance tests was fabricated. The administration flow channel has a hole on the tip end of the flow channel. The microperfusion flow channel starts from the root side of the needle, turns around at the needle‐tip end, and returns back to the root side of the needle. It has a perforated membrane on the surface of the area placed in the skin when inserted. Glucose is administrated through the flow channel, and glucose concentration of the skin is measured by microperfusion before and after administration. When the perfusate is perfused into the microperfusion flow channel, since the glucose concentration of the skin is higher than the perfusate, glucose contained in the skin's interstitial fluid moves into the flow channel through the perforated membrane by concentration diffusion, and the glucose can be collected. The needle's administration and glucose‐collecting functions were evaluated in the skin of mice.

Electronics and Communications in JapanVol. 108(2)
Tohoku University (JP)
Openalex Percentile: Top 88%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.