Nanosecond PD Currents Under Needle-Plane Electrode With Different Electrode Radii Over Four Kinds of Polymer Films

Partial discharge (PD) degradation in high-voltage and/or high-field equipment is a major hazard that can result in equipment breakdown. Despite extensive research, PDs remain challenging to understand owing to their strong dependence on experimental conditions. Fast-PD waveforms have garnered significant interest owing to recent advancements in high-speed oscilloscopes, which has facilitated the measurement of PD current shapes and the direct analysis of nanosecond-order waveforms. PD currents typically flow in 10–20 ns and PD measurement circuit length must be sufficiently short to get correct PD waveforms. The total length of our PD current-flow circuit is made to be less than 15 cm to get correct waveforms. The electrode consists of a simple needle-plane electrode with small discharge gaps of 0–150 μm. The needle diameter is 1 mm with tip radii of 30 μm and 300 μm. An a.c. peak voltage of 2000 V at 50–1000 Hz are applied to polyimide, polyethylene terephthalate, polyethylene naphthalate, and polycarbonate films. The PD current waveforms exhibit approximately 5 ns peak time for both positive and negative pulses and the pulse width at half height of the peak value are 5–15 ns. Those times vary depending on the film material, discharge gap length and needle tip radius. The applied a.c. voltage frequency dependence of these times are small over the applied voltage frequencies. Moreover, nuclear magnetic resonance analyses suggest that the current wave form differences may occur with the dipole movement affects the trapped charge movements.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2025-05-02
DOI
https://doi.org/10.1109/tdei.2025.3566693
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanosecond PD Currents Under Needle-Plane Electrode With Different Electrode Radii Over Four Kinds of Polymer Films

Tatsuki Okamoto, Hiroaki Uehara, Toshihiro Takahashi, Yuta Makino
IEEE Transactions on Dielectrics and Electrical Insulation
Analytical Chemistry and Sensors
article

Nanosecond PD Currents Under Needle-Plane Electrode With Different Electrode Radii Over Four Kinds of Polymer Films

Tatsuki Okamoto, Hiroaki Uehara, Toshihiro Takahashi, Yuta Makino
article en

Abstract

Partial discharge (PD) degradation in high-voltage and/or high-field equipment is a major hazard that can result in equipment breakdown. Despite extensive research, PDs remain challenging to understand owing to their strong dependence on experimental conditions. Fast-PD waveforms have garnered significant interest owing to recent advancements in high-speed oscilloscopes, which has facilitated the measurement of PD current shapes and the direct analysis of nanosecond-order waveforms. PD currents typically flow in 10–20 ns and PD measurement circuit length must be sufficiently short to get correct PD waveforms. The total length of our PD current-flow circuit is made to be less than 15 cm to get correct waveforms. The electrode consists of a simple needle-plane electrode with small discharge gaps of 0–150 μm. The needle diameter is 1 mm with tip radii of 30 μm and 300 μm. An a.c. peak voltage of 2000 V at 50–1000 Hz are applied to polyimide, polyethylene terephthalate, polyethylene naphthalate, and polycarbonate films. The PD current waveforms exhibit approximately 5 ns peak time for both positive and negative pulses and the pulse width at half height of the peak value are 5–15 ns. Those times vary depending on the film material, discharge gap length and needle tip radius. The applied a.c. voltage frequency dependence of these times are small over the applied voltage frequencies. Moreover, nuclear magnetic resonance analyses suggest that the current wave form differences may occur with the dipole movement affects the trapped charge movements.

IEEE Transactions on Dielectrics and Electrical InsulationVol. 32(6)
Central Research Institute of Electric Power Industry (JP), Kanto Gakuin University (JP)
Affordable and clean energy
Openalex Percentile: Top 88%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nanosecond PD Currents Under Needle-Plane Electrode With Different Electrode Radii Over Four Kinds of Polymer Films — Tatsuki Okamoto, Hiroaki Uehara, et al. · IEEE Transactions on Dielectrics and Electrical Insulation (2025) | TGRS Research Map | TGRS