Dual Apodization Maximizes Charge Resolution and Frequency Precision in Charge Detection Mass Spectrometry

Charge detection mass spectrometry (CD-MS) is a single-particle technique in which the masses of individual ions are determined from simultaneous measurements of their <i>m</i>/<i>z</i> ratio and charge. Ions are trapped in an electrostatic linear ion trap and oscillate back and forth through a detection cylinder coupled to a low noise charge sensitive amplifier. The resulting signal is analyzed using short-time Fourier transforms (STFTs) to determine the <i>m</i>/<i>z</i> ratio and charge. The <i>m</i>/<i>z</i> ratio is determined from the oscillation frequency, and the charge is obtained from the magnitude of the fundamental. Here we compare the methods used to analyze time domain data for single ion measurements including STORI plots. We conclude that the original STFT approach remains the best method for the analysis of CD-MS data. However, there are many ways of implementing the STFT approach. We compare the options with the goal of maximizing precision of the charge and <i>m</i>/<i>z</i> determinations while simultaneously maximizing the number of ions that are detected. A variety of apodization methods are compared, and the effects of scalloping loss, equivalent noise bandwidth, computation time, window length, and step size are evaluated. Maximizing the precision of the charge and <i>m</i>/<i>z</i> determinations places conflicting constraints on the window length, and we conclude that a dual apodization strategy, with different window lengths, provides the most robust approach to analyzing results for the broad range of different samples that can be measured by CD-MS.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-05-02
DOI
https://doi.org/10.1021/jasms.5c00049
Citations
2
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual Apodization Maximizes Charge Resolution and Frequency Precision in Charge Detection Mass Spectrometry

Martin F. Jarrold, Raj A. Parikh
2 citations
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
1.51
article

Dual Apodization Maximizes Charge Resolution and Frequency Precision in Charge Detection Mass Spectrometry

Martin F. Jarrold, Raj A. Parikh
article en
2 citations

Abstract

Charge detection mass spectrometry (CD-MS) is a single-particle technique in which the masses of individual ions are determined from simultaneous measurements of their <i>m</i>/<i>z</i> ratio and charge. Ions are trapped in an electrostatic linear ion trap and oscillate back and forth through a detection cylinder coupled to a low noise charge sensitive amplifier. The resulting signal is analyzed using short-time Fourier transforms (STFTs) to determine the <i>m</i>/<i>z</i> ratio and charge. The <i>m</i>/<i>z</i> ratio is determined from the oscillation frequency, and the charge is obtained from the magnitude of the fundamental. Here we compare the methods used to analyze time domain data for single ion measurements including STORI plots. We conclude that the original STFT approach remains the best method for the analysis of CD-MS data. However, there are many ways of implementing the STFT approach. We compare the options with the goal of maximizing precision of the charge and <i>m</i>/<i>z</i> determinations while simultaneously maximizing the number of ions that are detected. A variety of apodization methods are compared, and the effects of scalloping loss, equivalent noise bandwidth, computation time, window length, and step size are evaluated. Maximizing the precision of the charge and <i>m</i>/<i>z</i> determinations places conflicting constraints on the window length, and we conclude that a dual apodization strategy, with different window lengths, provides the most robust approach to analyzing results for the broad range of different samples that can be measured by CD-MS.

Journal of the American Society for Mass SpectrometryVol. 36(6)
Indiana University Bloomington (US)
National Institute of General Medical Sciences
Affordable and clean energy
Openalex Percentile: Top 19%
Mass Spectrometry Techniques and Applications
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.