Evaluation of the Accuracy and Precision of the Mindray BC-5380 Hematology Analyzer in Predilute Mode Predilute Against Hemoglobin Examination in Capillary Blood

Technological advances affect the automation of laboratory equipment, one of which is haemoglobin examination with a haematology analyzer that has several modes of examination to improve accuracy and precision. The haemoglobin test data at RSU Fastabiq Sehat PKU Muhammadiyah Pati reached 25,365 tests. Predilute mode on the Mindray BC-5380 haematology analyser is rarely used, only about 2%, very much different from the use of Whole Blood (WB) mode which reaches a percentage of 98%. This study aims to evaluate the accuracy and precision of the Hematology Analyzer Mindray BC-5380 in Predilute mode for measuring haemoglobin levels using capillary blood at RSU Fastabiq Sehat PKU Muhammadiyah Pati. The methodology used in this study was descriptive quantitative with a cross-sectional approach. Data was obtained through measurement of haemoglobin using the device, which was then analysed to assess accuracy and precision. The results showed a bias value of 2.58%, indicating good accuracy. The coefficient of variation (CV) value of 5.52% exceeded the limit set by the manufacturer, indicating poor precision. Further evaluation using the Levey-Jenning graph and Westgard's rule indicated a 12s deviation on the fifth day, indicating the possibility of systematic or random errors. The Mindray BC-5380 predilute mode haematology analyser had good accuracy of haemoglobin levels in capillary blood, but poor precision compared to the manufacturer's values.

Authors

Publication Details

Journal
Jaringan Laboratorium Medis
Published
2025-05-01
DOI
https://doi.org/10.31983/jlm.v7i1.12778
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Accuracy and Precision of the Mindray BC-5380 Hematology Analyzer in Predilute Mode Predilute Against Hemoglobin Examination in Capillary Blood

Arief Adi Saputro, Yayuk Mundriyastutik, Dwi Apriliani
Jaringan Laboratorium Medis
Clinical Laboratory Practices and Quality Control
article

Evaluation of the Accuracy and Precision of the Mindray BC-5380 Hematology Analyzer in Predilute Mode Predilute Against Hemoglobin Examination in Capillary Blood

Arief Adi Saputro, Yayuk Mundriyastutik, Dwi Apriliani
article en

Abstract

Technological advances affect the automation of laboratory equipment, one of which is haemoglobin examination with a haematology analyzer that has several modes of examination to improve accuracy and precision. The haemoglobin test data at RSU Fastabiq Sehat PKU Muhammadiyah Pati reached 25,365 tests. Predilute mode on the Mindray BC-5380 haematology analyser is rarely used, only about 2%, very much different from the use of Whole Blood (WB) mode which reaches a percentage of 98%. This study aims to evaluate the accuracy and precision of the Hematology Analyzer Mindray BC-5380 in Predilute mode for measuring haemoglobin levels using capillary blood at RSU Fastabiq Sehat PKU Muhammadiyah Pati. The methodology used in this study was descriptive quantitative with a cross-sectional approach. Data was obtained through measurement of haemoglobin using the device, which was then analysed to assess accuracy and precision. The results showed a bias value of 2.58%, indicating good accuracy. The coefficient of variation (CV) value of 5.52% exceeded the limit set by the manufacturer, indicating poor precision. Further evaluation using the Levey-Jenning graph and Westgard's rule indicated a 12s deviation on the fifth day, indicating the possibility of systematic or random errors. The Mindray BC-5380 predilute mode haematology analyser had good accuracy of haemoglobin levels in capillary blood, but poor precision compared to the manufacturer's values.

Jaringan Laboratorium MedisVol. 7(1)
Openalex Percentile: Top 88%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.