Lightweight and universal deep learning model for fast proton spot dose calculation at arbitrary energies

<i>Objective.</i>To better integrate into processes like rapid adaptive planning and quality assurance, this study aims to propose a lightweight and universal proton spot dose calculation model suitable for arbitrary energies.<i>Approach.</i>Given the alignment between the characteristics of proton spot dose deposition and the sequence learning capabilities of the long short-term memory (LSTM) network, the lightweight model, multi-energy dose LSTM (MED-LSTM), is proposed. To comprehensively investigate the effectiveness of model, we trained and evaluated it on prostate, nasopharynx, and lung cases consistently.<i>Main results</i>. Regarding the results for spot dose, the prostate, nasopharynx, and lung models achieved average gamma passing rates of 99.93%, 99.81%, and 99.89% respectively under the (1%, 3 mm) criterion. Under the (1%, 1 mm) criterion, the rates were 99.06%, 97.18%, and 98.32%, respectively. For the intensity-modulated proton therapy plan dose, the prostate model achieved optimal performance with gamma passing rates of 99.88% and 98.52% under the (1%, 3 mm) and (1%, 1 mm) criteria, respectively. Following this, the lung model achieved rates of 99.22% and 93.41%. The nasopharynx model exhibited the poorest performance, with rates of 99.56% and 88.95%, respectively. It is evident that the MED-LSTM model demonstrates extremely high dose calculation accuracy in most cases. However, visible deviations occur in some spot samples for the nasopharynx and lung cases due to structural tissue differences.<i>Significance.</i>The MED-LSTM model can rapidly and accurately determine the proton spot dose at any energy with relatively low number of parameters. This exciting outcome holds broad prospects for applications and research directions.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-05-02
DOI
https://doi.org/10.1088/1361-6560/add3b9
Citations
1
Primary Topic
Machine Learning in Materials Science
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lightweight and universal deep learning model for fast proton spot dose calculation at arbitrary energies

Y. Zeng, Zhiyong Yang, Muyu Liu, Shuoyan Chen et al.
1 citations
Physics in Medicine and Biology
Machine Learning in Materials Science
0.52
article

Lightweight and universal deep learning model for fast proton spot dose calculation at arbitrary energies

Y. Zeng, Zhiyong Yang, Muyu Liu, Shuoyan Chen, Qi Zhang, B. Pang, Hong Quan, Yu Chang
article en
1 citations

Abstract

<i>Objective.</i>To better integrate into processes like rapid adaptive planning and quality assurance, this study aims to propose a lightweight and universal proton spot dose calculation model suitable for arbitrary energies.<i>Approach.</i>Given the alignment between the characteristics of proton spot dose deposition and the sequence learning capabilities of the long short-term memory (LSTM) network, the lightweight model, multi-energy dose LSTM (MED-LSTM), is proposed. To comprehensively investigate the effectiveness of model, we trained and evaluated it on prostate, nasopharynx, and lung cases consistently.<i>Main results</i>. Regarding the results for spot dose, the prostate, nasopharynx, and lung models achieved average gamma passing rates of 99.93%, 99.81%, and 99.89% respectively under the (1%, 3 mm) criterion. Under the (1%, 1 mm) criterion, the rates were 99.06%, 97.18%, and 98.32%, respectively. For the intensity-modulated proton therapy plan dose, the prostate model achieved optimal performance with gamma passing rates of 99.88% and 98.52% under the (1%, 3 mm) and (1%, 1 mm) criteria, respectively. Following this, the lung model achieved rates of 99.22% and 93.41%. The nasopharynx model exhibited the poorest performance, with rates of 99.56% and 88.95%, respectively. It is evident that the MED-LSTM model demonstrates extremely high dose calculation accuracy in most cases. However, visible deviations occur in some spot samples for the nasopharynx and lung cases due to structural tissue differences.<i>Significance.</i>The MED-LSTM model can rapidly and accurately determine the proton spot dose at any energy with relatively low number of parameters. This exciting outcome holds broad prospects for applications and research directions.

Physics in Medicine and BiologyVol. 70(10)
Union Hospital (HK), Wuhan University of Technology (CN), Wuhan University (CN), Wuhan Union Hospital (CN), Union Hospital (CN), Wuhan University of Science and Technology (CN), Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 39%
Machine Learning in Materials Science
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.