Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems

Negative pressure wound therapy (NPWT) systems facilitate wound healing by applying sub-atmospheric pressure to the wound bed, which promotes granulation tissue formation and reduces inflammation. Wound dressings can be used with these systems to enhance healing; however, the effects of dressings on NPWT device performance are challenging to assess. The purpose of this study was to develop a benchtop flesh analog model for testing the compatibility of wound dressing materials with NPWT devices. In this study, a chitosan-based advanced wound care device was evaluated for its effects on NPWT performance under maximum and minimum therapy pressures. The goal was to use the model to compare pressure readings and fluid collection for samples with and without the chitosan wound care device. The benchtop model was constructed using a plastic box connected to multiple pressure gauges. A circular defect was created on a piece of pork belly, used as the flesh analog, and inserted into the box. The defect was filled with standard NPWT foam or foam combined with the wound dressing. Simulated body fluid containing bovine serum was added to the box, which was then tested at either maximum (-200 mmHg) or minimum (-25 mmHg) pressures for 72 h. Pressure and fluid collection were recorded every 12 h. The NPWT system successfully maintained pressure over the 72 h test period, both with and without the test dressings. The addition of the wound dressings did not impact fluid collection. The test box proved effective as a benchtop model, as it could be sealed and maintained vacuum conditions over the 72 h testing period. This model successfully demonstrated its utility in evaluating the compatibility of wound dressing materials with NPWT systems.

Authors

Institutions

Publication Details

Journal
Journal of Visualized Experiments
Published
2025-05-02
DOI
https://doi.org/10.3791/67890
Primary Topic
Surgical Sutures and Adhesives
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems

Jessica Amber Jennings, Andrew Blass Watson, Joel D. Bumgardner, Haley Pruitt
Journal of Visualized Experiments
Surgical Sutures and Adhesives
article

Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems

Jessica Amber Jennings, Andrew Blass Watson, Joel D. Bumgardner, Haley Pruitt
article en

Abstract

Negative pressure wound therapy (NPWT) systems facilitate wound healing by applying sub-atmospheric pressure to the wound bed, which promotes granulation tissue formation and reduces inflammation. Wound dressings can be used with these systems to enhance healing; however, the effects of dressings on NPWT device performance are challenging to assess. The purpose of this study was to develop a benchtop flesh analog model for testing the compatibility of wound dressing materials with NPWT devices. In this study, a chitosan-based advanced wound care device was evaluated for its effects on NPWT performance under maximum and minimum therapy pressures. The goal was to use the model to compare pressure readings and fluid collection for samples with and without the chitosan wound care device. The benchtop model was constructed using a plastic box connected to multiple pressure gauges. A circular defect was created on a piece of pork belly, used as the flesh analog, and inserted into the box. The defect was filled with standard NPWT foam or foam combined with the wound dressing. Simulated body fluid containing bovine serum was added to the box, which was then tested at either maximum (-200 mmHg) or minimum (-25 mmHg) pressures for 72 h. Pressure and fluid collection were recorded every 12 h. The NPWT system successfully maintained pressure over the 72 h test period, both with and without the test dressings. The addition of the wound dressings did not impact fluid collection. The test box proved effective as a benchtop model, as it could be sealed and maintained vacuum conditions over the 72 h testing period. This model successfully demonstrated its utility in evaluating the compatibility of wound dressing materials with NPWT systems.

Journal of Visualized Experiments(219)
University of Tennessee Health Science Center (US), University of Memphis (US)
Openalex Percentile: Top 84%
Surgical Sutures and Adhesives
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.