Comprehensive physical evaluation of potential CT contrast agents: Integrating Monte Carlo transport simulation and radiation shielding Analysis

To perform a comprehensive physical-level assessment of 13 contrast agents, including those with potential applications in CT imaging, focusing on their radiation shielding characteristics and transport behaviors—such as energy deposition, collision frequency, and attenuation performance—under low-energy X-ray conditions. A dual-method framework was adopted. Geant4 Monte Carlo simulations were used to construct an X-ray tube model and simulate contrast agent interactions in a breast-equivalent water phantom, enabling analysis of microscopic radiation transport parameters including energy deposition, track length, and collision frequency. In parallel, Phy-X/PSD software was used to calculate macroscopic attenuation indices, including the linear attenuation coefficient (LAC), mass attenuation coefficient (MAC), mean free path (MFP), half-value layer (HVL), and exposure buildup factor (EBF), over a wide photon energy range. The study revealed a strong consistency between radiation shielding metrics and transport characteristics across the same energy ranges. For instance, iothalamate meglumine exhibited the highest energy deposition (0.08560 MeV), shortest MFP (1.13 cm), and highest collision frequency (∼5.24×10 8 ), indicating excellent attenuation potential in the low-energy CT range. Gadolinium- and iron-based agents, while traditionally used in MR imaging, showed distinctive and stable transport behavior at medium-to-high energies, suggesting promising utility in CT or dual-modality applications. These findings highlight the importance of integrating microscopic transport analysis with macroscopic shielding evaluation to fully characterize contrast agent performance. The study provides a validated theoretical foundation for contrast agent screening and optimization in X-ray imaging, and supports future research into clinical applicability and biological safety of emerging contrast materials.

Authors

Institutions

Publication Details

Journal
Radiation Medicine and Protection
Published
2025-05-02
DOI
https://doi.org/10.1016/j.radmp.2025.04.005
Citations
1
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive physical evaluation of potential CT contrast agents: Integrating Monte Carlo transport simulation and radiation shielding Analysis

Yulong Zhang, Jinjia Cao, Xiaochang Zheng, Yadong Zhang et al.
1 citations
Radiation Medicine and Protection
Radiation Shielding Materials Analysis
0.52
article

Comprehensive physical evaluation of potential CT contrast agents: Integrating Monte Carlo transport simulation and radiation shielding Analysis

Yulong Zhang, Jinjia Cao, Xiaochang Zheng, Yadong Zhang, Yanjun Wang, Wei Chen
article en
1 citations

Abstract

To perform a comprehensive physical-level assessment of 13 contrast agents, including those with potential applications in CT imaging, focusing on their radiation shielding characteristics and transport behaviors—such as energy deposition, collision frequency, and attenuation performance—under low-energy X-ray conditions. A dual-method framework was adopted. Geant4 Monte Carlo simulations were used to construct an X-ray tube model and simulate contrast agent interactions in a breast-equivalent water phantom, enabling analysis of microscopic radiation transport parameters including energy deposition, track length, and collision frequency. In parallel, Phy-X/PSD software was used to calculate macroscopic attenuation indices, including the linear attenuation coefficient (LAC), mass attenuation coefficient (MAC), mean free path (MFP), half-value layer (HVL), and exposure buildup factor (EBF), over a wide photon energy range. The study revealed a strong consistency between radiation shielding metrics and transport characteristics across the same energy ranges. For instance, iothalamate meglumine exhibited the highest energy deposition (0.08560 MeV), shortest MFP (1.13 cm), and highest collision frequency (∼5.24×10 8 ), indicating excellent attenuation potential in the low-energy CT range. Gadolinium- and iron-based agents, while traditionally used in MR imaging, showed distinctive and stable transport behavior at medium-to-high energies, suggesting promising utility in CT or dual-modality applications. These findings highlight the importance of integrating microscopic transport analysis with macroscopic shielding evaluation to fully characterize contrast agent performance. The study provides a validated theoretical foundation for contrast agent screening and optimization in X-ray imaging, and supports future research into clinical applicability and biological safety of emerging contrast materials.

Radiation Medicine and ProtectionVol. 6(3)
University of South China (CN)
Openalex Percentile: Top 39%
Radiation Shielding Materials Analysis
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.