Electrical impedance tomography in calves with bovine respiratory disease: correlations with clinical and blood gas findings

Bovine respiratory disease (BRD) is a multifactorial global problem associated with long-term deleterious effects on the well-being of calves and marked financial losses. Prompt diagnosis of BRD, monitoring the success of treatment, and providing an accurate prognosis remain challenging because current methods for stall-side diagnosis are inadequate. To improve diagnosis in addition to clinical and morphological findings and gain insight into the respiratory dynamics of BRD, thoracic electrical impedance tomography (EIT) was used to evaluate calves with BRD (Group D; <i>n</i> = 42) and healthy calves (Group H; <i>n</i> = 13). Thoracic EIT is a non-invasive method of quantifying differences in impedance changes between various lung regions and impedance changes over time. A belt with 32 equidistantly mounted electrodes was placed around the thorax of non-sedated calves of both groups to measure impedance changes during respiration. The results were compared with the clinical findings and the California BRD scores. Compared with group H, Group D had decreased ventilation in the ventral lung regions (<i>p</i> = 0.05); ventilation shifted to the left lung lobes in calves with marked auscultatory changes (<i>p</i> = 0.013). In addition, the quartile ventilation ratio on inspiration (V<sub>QRi</sub>), used to quantify changes in impedance during inspiration, differed significantly between the two groups (<i>p</i> = 0.0039). Of all the EIT parameters, V<sub>QRi</sub> correlated most closely with paO<sub>2</sub> and the A-a-gradient and was significantly lower in group D than in group H (<i>p</i> = 0.061). The results of EIT revealed differences in the inspiratory dynamics of clinically healthy and ill calves and correlated with the clinical and blood gas findings. Thus, EIT can be used alone or together with other diagnostic tools to identify and monitor BRD in calves.

Authors

Institutions

Publication Details

Journal
Frontiers in Veterinary Science
Published
2025-05-01
DOI
https://doi.org/10.3389/fvets.2025.1556943
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical impedance tomography in calves with bovine respiratory disease: correlations with clinical and blood gas findings

Christian Gerspach, U. Bleul, Andreas D. Waldmann, Fabienne Kluser
Frontiers in Veterinary Science
Electrical and Bioimpedance Tomography
article

Electrical impedance tomography in calves with bovine respiratory disease: correlations with clinical and blood gas findings

Christian Gerspach, U. Bleul, Andreas D. Waldmann, Fabienne Kluser
article en

Abstract

Bovine respiratory disease (BRD) is a multifactorial global problem associated with long-term deleterious effects on the well-being of calves and marked financial losses. Prompt diagnosis of BRD, monitoring the success of treatment, and providing an accurate prognosis remain challenging because current methods for stall-side diagnosis are inadequate. To improve diagnosis in addition to clinical and morphological findings and gain insight into the respiratory dynamics of BRD, thoracic electrical impedance tomography (EIT) was used to evaluate calves with BRD (Group D; <i>n</i> = 42) and healthy calves (Group H; <i>n</i> = 13). Thoracic EIT is a non-invasive method of quantifying differences in impedance changes between various lung regions and impedance changes over time. A belt with 32 equidistantly mounted electrodes was placed around the thorax of non-sedated calves of both groups to measure impedance changes during respiration. The results were compared with the clinical findings and the California BRD scores. Compared with group H, Group D had decreased ventilation in the ventral lung regions (<i>p</i> = 0.05); ventilation shifted to the left lung lobes in calves with marked auscultatory changes (<i>p</i> = 0.013). In addition, the quartile ventilation ratio on inspiration (V<sub>QRi</sub>), used to quantify changes in impedance during inspiration, differed significantly between the two groups (<i>p</i> = 0.0039). Of all the EIT parameters, V<sub>QRi</sub> correlated most closely with paO<sub>2</sub> and the A-a-gradient and was significantly lower in group D than in group H (<i>p</i> = 0.061). The results of EIT revealed differences in the inspiratory dynamics of clinically healthy and ill calves and correlated with the clinical and blood gas findings. Thus, EIT can be used alone or together with other diagnostic tools to identify and monitor BRD in calves.

Frontiers in Veterinary ScienceVol. 12
University of Zurich (CH), Center for Pediatric Endocrinology Zurich (CH)
Openalex Percentile: Top 93%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.