Environmental impact of PFAS incineration

• Incineration is a typical method of disposal for fluorosurfactants including PFAS. • First-order thermodynamic model indicates the reaction enthalpy of fluorosurfactant solutions are dependent on water content. • Incomplete combustion of fluorosurfactants at low temperature may result in the release of high global warming potential (GWP) waste products. • Formation of fluoroalkanes increases GWP impact and may occur low combustion temperatures. A first-order thermodynamic model for the incineration of poly- and per-fluorinated alkyl substances (PFAS) in aqueous film-forming foam (AFFF) in a rotary kiln incinerator (i.e., a typical hazardous waste disposal) as well as decomposition at lower temperatures used in waste-to-energy incineration processes is used to discuss the global warming potential (GWP) impact of such incineration. Approximate orders of magnitude of tons of CO 2 per ton of AFFF combusted are determined based on AFFF disposal data from a survey on the incineration of the US military’s AFFF supplies for complete and incomplete combustion of the AFFF wastewater. The model suggests that incomplete combustion of fluorosurfactants at low temperature will result in the release of high GWP waste products such as CF-alkanes. The risk of incomplete PFAS combustion may be amplified with diluted AFFF streams as the net reaction will be endothermic, potentially depressing the reactor temperature and promoting the formation of high-GWP byproducts. For more complete combustion cases evaluated, the estimated emission is on the order of 2 metric tons of CO 2 per ton of AFFF combusted. In the worst-case scenario with CF-alkane release, the expected emission is between 439 and 537 metric tons of CO 2 per ton of AFFF combusted. In this scenario, the incineration impact of 10,007 metric tons of AFFF combusted is equivalent to the emissions resulting from firing an average coal-fired power plant for approximately 3.6 years or the annual emissions of approximately 1 million automobiles.

Authors

Institutions

Publication Details

Journal
Waste Management Bulletin
Published
2025-05-01
DOI
https://doi.org/10.1016/j.wmb.2025.100202
Citations
3
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
2.58
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Environmental impact of PFAS incineration

Jason F. Kovacs, Young I. Cho, Richard B. Higgins, Nathalie Ionesco
3 citations
Waste Management Bulletin
Per- and polyfluoroalkyl substances research
2.58
article

Environmental impact of PFAS incineration

Jason F. Kovacs, Young I. Cho, Richard B. Higgins, Nathalie Ionesco
article en
3 citations

Abstract

• Incineration is a typical method of disposal for fluorosurfactants including PFAS. • First-order thermodynamic model indicates the reaction enthalpy of fluorosurfactant solutions are dependent on water content. • Incomplete combustion of fluorosurfactants at low temperature may result in the release of high global warming potential (GWP) waste products. • Formation of fluoroalkanes increases GWP impact and may occur low combustion temperatures. A first-order thermodynamic model for the incineration of poly- and per-fluorinated alkyl substances (PFAS) in aqueous film-forming foam (AFFF) in a rotary kiln incinerator (i.e., a typical hazardous waste disposal) as well as decomposition at lower temperatures used in waste-to-energy incineration processes is used to discuss the global warming potential (GWP) impact of such incineration. Approximate orders of magnitude of tons of CO 2 per ton of AFFF combusted are determined based on AFFF disposal data from a survey on the incineration of the US military’s AFFF supplies for complete and incomplete combustion of the AFFF wastewater. The model suggests that incomplete combustion of fluorosurfactants at low temperature will result in the release of high GWP waste products such as CF-alkanes. The risk of incomplete PFAS combustion may be amplified with diluted AFFF streams as the net reaction will be endothermic, potentially depressing the reactor temperature and promoting the formation of high-GWP byproducts. For more complete combustion cases evaluated, the estimated emission is on the order of 2 metric tons of CO 2 per ton of AFFF combusted. In the worst-case scenario with CF-alkane release, the expected emission is between 439 and 537 metric tons of CO 2 per ton of AFFF combusted. In this scenario, the incineration impact of 10,007 metric tons of AFFF combusted is equivalent to the emissions resulting from firing an average coal-fired power plant for approximately 3.6 years or the annual emissions of approximately 1 million automobiles.

Waste Management BulletinVol. 3(3)
Somerville Hospital (US), Drexel University (US)
Climate action
Openalex Percentile: Top 12%
Per- and polyfluoroalkyl substances research
2.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.