Pathological manifestations in a prestressed concrete flat slab building - a case study: part I - structure analysis.

Prestressed concrete flat slabs with unbonded tendons are widely used in Brazil due to their advantages. However, the bold achieved with the use of prestressed buildings often results in highly complex projects and non-trivial considerations in the engineer's daily work. This work aims to present a case study of a commercial building constructed in Rio Grande do Sul, consisting of prestressed concrete flat slabs with unbonded tendons, where pathological manifestations occurred even during the construction phase, such as excessive deflections, cracks in the prestressed slabs, and some partial ruptures of structural elements. The work presents the pathological manifestations at the building and the structural analysis, as well as a succinct presentation of the reinforcement techniques used.

Authors

Institutions

Publication Details

Journal
Revista ALCONPAT
Published
2025-05-01
DOI
https://doi.org/10.21041/ra.v15i2.738
Primary Topic
Structural Engineering and Vibration Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pathological manifestations in a prestressed concrete flat slab building - a case study: part I - structure analysis.

Paulo Jorge Sarkis, Almir Barros da Silva Santos Neto, Jorge Martins Sarkis, André Lübeck
Revista ALCONPAT
Structural Engineering and Vibration Analysis
article

Pathological manifestations in a prestressed concrete flat slab building - a case study: part I - structure analysis.

Paulo Jorge Sarkis, Almir Barros da Silva Santos Neto, Jorge Martins Sarkis, André Lübeck
article en

Abstract

Prestressed concrete flat slabs with unbonded tendons are widely used in Brazil due to their advantages. However, the bold achieved with the use of prestressed buildings often results in highly complex projects and non-trivial considerations in the engineer's daily work. This work aims to present a case study of a commercial building constructed in Rio Grande do Sul, consisting of prestressed concrete flat slabs with unbonded tendons, where pathological manifestations occurred even during the construction phase, such as excessive deflections, cracks in the prestressed slabs, and some partial ruptures of structural elements. The work presents the pathological manifestations at the building and the structural analysis, as well as a succinct presentation of the reinforcement techniques used.

Revista ALCONPATVol. 15(2)
Universidade Federal de Santa Maria (BR), Hospital Universitário de Santa Maria (BR)
Openalex Percentile: Top 91%
Structural Engineering and Vibration Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.