Micropillar array-based microfluidic device for electrochemical monitoring of cell culture health

Glucose levels serve as a fundamental indicator of cell health, reflecting crucial aspects of cellular metabolism and energy production. While effective, traditional methods such as spectrophotometry and chromatography have limitations, such as labour-intensive sample collection, reliance on bulky equipment, extensive sample preparation, and prolonged experimental durations. To address these issues, we introduce a micropillar-based microfluidic electrochemical device (MED) for real-time monitoring of glucose levels in diverse cell culture systems, including human induced pluripotent stem cells (hiPSCs) and murine fibroblast cells (GP + E86). This biosensor demonstrates a linear range of 0.025-1.50 mM and a high sensitivity of 4.71 ± 0.13 μA. mM<sup>-1</sup>, and a low limit of detection of 19.10 ± 0.50 μM. The MED not only delivered fast glucose measurements with accuracy and reliability comparable to ultra-high-performance liquid chromatography (UHPLC) but was also specifically evaluated on GP + E86 murine fibroblast cells at varying seeding densities (1:5 and 1:10 ratios), across different culturing times to accurately monitor dynamic metabolic shifts associated with various growth phases. Furthermore, the MED effectively detected significant changes in glucose consumption in hiPSCs cell cultures contaminated with Escherichia coli (E. coli), highlighting its potential for early contamination detection. Integrating non-invasive, continuous monitoring platforms enhances the reliability of experimental outcomes by enabling cell health monitoring without disrupting the cell culture process. This approach enables real-time monitoring of cell cultures ensuring accurate detection of metabolic changes and early detection of media contamination.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2025-05-01
DOI
https://doi.org/10.1016/j.bios.2025.117534
Citations
5
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
3.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Micropillar array-based microfluidic device for electrochemical monitoring of cell culture health

Víctor J. Cadarso, Jann Harberts, Azadeh Nilghaz, Masoud Khazaei et al.
5 citations
Biosensors and Bioelectronics
Microfluidic and Capillary Electrophoresis Applications
3.37
article

Micropillar array-based microfluidic device for electrochemical monitoring of cell culture health

Víctor J. Cadarso, Jann Harberts, Azadeh Nilghaz, Masoud Khazaei, Nicolas H. Voelcker, Muamer Dervisevic, Michael Shola David, Kenneth Galbraith
article en
5 citations

Abstract

Glucose levels serve as a fundamental indicator of cell health, reflecting crucial aspects of cellular metabolism and energy production. While effective, traditional methods such as spectrophotometry and chromatography have limitations, such as labour-intensive sample collection, reliance on bulky equipment, extensive sample preparation, and prolonged experimental durations. To address these issues, we introduce a micropillar-based microfluidic electrochemical device (MED) for real-time monitoring of glucose levels in diverse cell culture systems, including human induced pluripotent stem cells (hiPSCs) and murine fibroblast cells (GP + E86). This biosensor demonstrates a linear range of 0.025-1.50 mM and a high sensitivity of 4.71 ± 0.13 μA. mM<sup>-1</sup>, and a low limit of detection of 19.10 ± 0.50 μM. The MED not only delivered fast glucose measurements with accuracy and reliability comparable to ultra-high-performance liquid chromatography (UHPLC) but was also specifically evaluated on GP + E86 murine fibroblast cells at varying seeding densities (1:5 and 1:10 ratios), across different culturing times to accurately monitor dynamic metabolic shifts associated with various growth phases. Furthermore, the MED effectively detected significant changes in glucose consumption in hiPSCs cell cultures contaminated with Escherichia coli (E. coli), highlighting its potential for early contamination detection. Integrating non-invasive, continuous monitoring platforms enhances the reliability of experimental outcomes by enabling cell health monitoring without disrupting the cell culture process. This approach enables real-time monitoring of cell cultures ensuring accurate detection of metabolic changes and early detection of media contamination.

Biosensors and BioelectronicsVol. 283
Deakin University (AU), Australian National Fabrication Facility (AU), TissuPath (AU), Monash University (AU)
Openalex Percentile: Top 8%
Microfluidic and Capillary Electrophoresis Applications
3.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.