C-19 | Comparative Efficacy and Safety of WATCHMAN FLX Versus WATCHMAN 2.5 for the Left Atrial Appendage Closure In Patients With Non-Valvular Atrial Fibrillation: An Updated Meta-Analysis

The WATCHMAN is a device designed to completely seal the left atrial appendage (LAA) in patients with atrial fibrillation and atrial flutter who are unable to tolerate long-term anticoagulant therapy due to risk of severe bleeding. The newer generation WATCHMAN FLX has been upgraded to address the various shortcomings of the first-generation WATCHMAN 2.5, including peri device leak, device-related thrombus (DRT), and challenging implantation in intricate LAA anatomy. This meta-analysis aims to compare the procedural and midterm outcomes of the two generations of WATCHMAN.

Authors

Institutions

Publication Details

Journal
Journal of the Society for Cardiovascular Angiography & Interventions
Published
2025-05-01
DOI
https://doi.org/10.1016/j.jscai.2025.103009
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

C-19 | Comparative Efficacy and Safety of WATCHMAN FLX Versus WATCHMAN 2.5 for the Left Atrial Appendage Closure In Patients With Non-Valvular Atrial Fibrillation: An Updated Meta-Analysis

Javeria Jamal, Yusra Javed, Tooba Asif, Mohammad Hamza Bin Abdul Malik et al.
Journal of the Society for Cardiovascular Angiography & Interventions
Atrial Fibrillation Management and Outcomes
article

C-19 | Comparative Efficacy and Safety of WATCHMAN FLX Versus WATCHMAN 2.5 for the Left Atrial Appendage Closure In Patients With Non-Valvular Atrial Fibrillation: An Updated Meta-Analysis

Javeria Jamal, Yusra Javed, Tooba Asif, Mohammad Hamza Bin Abdul Malik, S. M. Shaheedul Islam, Maryam Yousaf, Muhammad Usama Mehtab, Khadija Ahmad, Esha Dilawar, Maham Kubra, Zurria Asif, Tayyaba Younnas
article en

Abstract

The WATCHMAN is a device designed to completely seal the left atrial appendage (LAA) in patients with atrial fibrillation and atrial flutter who are unable to tolerate long-term anticoagulant therapy due to risk of severe bleeding. The newer generation WATCHMAN FLX has been upgraded to address the various shortcomings of the first-generation WATCHMAN 2.5, including peri device leak, device-related thrombus (DRT), and challenging implantation in intricate LAA anatomy. This meta-analysis aims to compare the procedural and midterm outcomes of the two generations of WATCHMAN.

Journal of the Society for Cardiovascular Angiography & InterventionsVol. 4(5)
Services Institute of Medical Sciences (PK), Nassau University Medical Center (US)
Zero hunger
Openalex Percentile: Top 83%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

C-19 | Comparative Efficacy and Safety of WATCHMAN FLX Versus WATCHMAN 2.5 for the Left Atrial Appendage Closure In Patients With Non-Valvular Atrial Fibrillation: An Updated Meta-Analysis — Javeria Jamal, Yusra Javed, et al. · Journal of the Society for Cardiovascular Angiography & Interventions (2025) | TGRS Research Map | TGRS