Correlation Between Preoperative Parameters of Sonography Videourodynamic Studies and Postoperative Outcomes in BPH Patients

Objective: To investigate the correlation between preoperative parameters of sonography videourodynamic studies (SVUDS), including maximum detrusor pressure (Pmax), bladder contractility index (BCI), prostate volume (PV), and intravesical prostatic protrusion distance (IPP), and postoperative efficacy in patients with benign prostatic hyperplasia (BPH) undergoing transurethral resection of the prostate (TURP), and to evaluate their predictive value for postoperative outcomes. Methods: Retrospective analysis of 74 BPH patients who underwent TURP at Shaoyang Central Hospital and The Second Affiliated Hospital of Guilin Medical University from August 2018 to August 2024. Preoperative Pmax, BCI, PV, IPP, and pre- and postoperative maximum urinary flow rate (Qmax) were collected. Postoperative Qmax improvement (postoperative Qmax − preoperative Qmax) was used to assess efficacy. Patients were divided into a good efficacy group (improvement ≥5.0 ml/s, n=49) and a poor efficacy group (improvement <5.0 ml/s, n=25). Univariate analysis was performed to compare differences between groups, and statistically significant parameters were further analyzed using ROC curves. Results: The median Qmax increased from 6.5 (4.8, 9.2) ml/s (preoperative) to 15.0 (9.6, 20.2) ml/s (postoperative). Univariate analysis showed no significant differences in preoperative Pmax or BCI between groups (P>0.05), while preoperative PV and IPP were significantly lower in the good efficacy group (P<0.05). ROC analysis revealed diagnostic efficacy (AUC) for PV and IPP as 0.656 and 0.682, respectively (P<0.05). Optimal cutoff values were PV >89.0 ml (specificity=0.918, sensitivity=0.440) and IPP >16.50 mm (specificity=0.531, sensitivity=0.760). Conclusion: Prostate volume (PV) and intravesical prostatic protrusion distance (IPP) correlate with postoperative urinary flow rate improvement. PV >89.0 ml demonstrates high specificity, while IPP >16.5 mm shows high sensitivity in predicting poor postoperative Q

Authors

Publication Details

Journal
Scholars Journal of Applied Medical Sciences
Published
2025-04-25
DOI
https://doi.org/10.36347/sjams.2025.v13i04.025
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation Between Preoperative Parameters of Sonography Videourodynamic Studies and Postoperative Outcomes in BPH Patients

Xiao Ning, Qiuxia Huang, Wenjie Qiu
Scholars Journal of Applied Medical Sciences
Ultrasound and Hyperthermia Applications
article

Correlation Between Preoperative Parameters of Sonography Videourodynamic Studies and Postoperative Outcomes in BPH Patients

Xiao Ning, Qiuxia Huang, Wenjie Qiu
article en

Abstract

Objective: To investigate the correlation between preoperative parameters of sonography videourodynamic studies (SVUDS), including maximum detrusor pressure (Pmax), bladder contractility index (BCI), prostate volume (PV), and intravesical prostatic protrusion distance (IPP), and postoperative efficacy in patients with benign prostatic hyperplasia (BPH) undergoing transurethral resection of the prostate (TURP), and to evaluate their predictive value for postoperative outcomes. Methods: Retrospective analysis of 74 BPH patients who underwent TURP at Shaoyang Central Hospital and The Second Affiliated Hospital of Guilin Medical University from August 2018 to August 2024. Preoperative Pmax, BCI, PV, IPP, and pre- and postoperative maximum urinary flow rate (Qmax) were collected. Postoperative Qmax improvement (postoperative Qmax − preoperative Qmax) was used to assess efficacy. Patients were divided into a good efficacy group (improvement ≥5.0 ml/s, n=49) and a poor efficacy group (improvement <5.0 ml/s, n=25). Univariate analysis was performed to compare differences between groups, and statistically significant parameters were further analyzed using ROC curves. Results: The median Qmax increased from 6.5 (4.8, 9.2) ml/s (preoperative) to 15.0 (9.6, 20.2) ml/s (postoperative). Univariate analysis showed no significant differences in preoperative Pmax or BCI between groups (P>0.05), while preoperative PV and IPP were significantly lower in the good efficacy group (P<0.05). ROC analysis revealed diagnostic efficacy (AUC) for PV and IPP as 0.656 and 0.682, respectively (P<0.05). Optimal cutoff values were PV >89.0 ml (specificity=0.918, sensitivity=0.440) and IPP >16.50 mm (specificity=0.531, sensitivity=0.760). Conclusion: Prostate volume (PV) and intravesical prostatic protrusion distance (IPP) correlate with postoperative urinary flow rate improvement. PV >89.0 ml demonstrates high specificity, while IPP >16.5 mm shows high sensitivity in predicting poor postoperative Q

Scholars Journal of Applied Medical SciencesVol. 13(04)
National Natural Science Foundation of China, Natural Science Foundation of Hunan Province
Openalex Percentile: Top 91%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.