Two-dimensional infrared spectroscopy using a fast-scanning interferometer and chirped pulse upconversion at 100 kHz

We report on a 100-kHz two-dimensional infrared (2DIR) spectrometer in the pump-probe geometry, which we apply to the measurement of the 2DIR spectrum of carboxyhemoglobin. The probe pulses are spectrally resolved by chirped-pulse upconversion (CPU) using a fast 2048-pixel line scan CMOS camera. The two-pulse pump sequence is generated using a conventional interferometer with a fast-scanning mechanical delay line allowing to achieve a scanning frequency of 2 Hz. The resulting modulation frequency of 3.1 kHz is large enough to shift the relevant signal away from the low-frequency noise of the laser source. The combined use of an interferometer on the pump side and of CPU on the probe side opens the way to an improved spectral resolution in both pump and probe dimensions, as compared to currently available 100-kHz 2DIR spectrometers based on pulse shapers and mercury-cadmium telluride detector arrays.

Authors

Institutions

Publication Details

Journal
The Journal of Chemical Physics
Published
2025-05-01
DOI
https://doi.org/10.1063/5.0261494
Citations
1
Primary Topic
Spectroscopy and Quantum Chemical Studies
Type
article
Field-Weighted Citation Impact
1.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-dimensional infrared spectroscopy using a fast-scanning interferometer and chirped pulse upconversion at 100 kHz

M. Joffre, Marc Hanna, Quentin Bournet, Florent Guichard et al.
1 citations
The Journal of Chemical Physics
Spectroscopy and Quantum Chemical Studies
1.25
article

Two-dimensional infrared spectroscopy using a fast-scanning interferometer and chirped pulse upconversion at 100 kHz

M. Joffre, Marc Hanna, Quentin Bournet, Florent Guichard, Andrei-Ovidiu Ersen, Michele Natile, Patrick Georges, Frédéric Druon, Yoann Zaouter, Adeline Bonvalet, Mindaugas Jonušas
article en
1 citations

Abstract

We report on a 100-kHz two-dimensional infrared (2DIR) spectrometer in the pump-probe geometry, which we apply to the measurement of the 2DIR spectrum of carboxyhemoglobin. The probe pulses are spectrally resolved by chirped-pulse upconversion (CPU) using a fast 2048-pixel line scan CMOS camera. The two-pulse pump sequence is generated using a conventional interferometer with a fast-scanning mechanical delay line allowing to achieve a scanning frequency of 2 Hz. The resulting modulation frequency of 3.1 kHz is large enough to shift the relevant signal away from the low-frequency noise of the laser source. The combined use of an interferometer on the pump side and of CPU on the probe side opens the way to an improved spectral resolution in both pump and probe dimensions, as compared to currently available 100-kHz 2DIR spectrometers based on pulse shapers and mercury-cadmium telluride detector arrays.

The Journal of Chemical PhysicsVol. 162(17)
Centre National de la Recherche Scientifique (FR), École Polytechnique (FR), Inserm (FR), Université Paris-Saclay (FR), Institut d’Optique Graduate School (FR), Laboratoire d'Optique Appliquée (FR), Laboratoire Charles Fabry (FR), Amplitude Systèmes (France) (FR), Université Paris 1 Panthéon-Sorbonne (FR)
Agence Nationale de la Recherche
Affordable and clean energy
Openalex Percentile: Top 22%
Spectroscopy and Quantum Chemical Studies
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.