Barbed and Non-Barbed Suture Materials for Ventral Hernia Repair: An Experimental Study

<b>Objectives:</b> The objective of this study was to assess the tissue response and strength of traditional and unidirectional suture materials, depending on the conditions of use and the timing following implantation. <b>Methods:</b> Eighty male Wistar rats were randomly assigned to four groups depending on the suture used: unidirectional absorbable V-loc<sup>TM</sup> 180 or non-absorbable V-loc<sup>TM</sup> PBT and traditional absorbable Maxon<sup>TM</sup> or non-absorbable Novafil<sup>TM</sup>. Three and six weeks following the closure of the abdominal wall defect (AWD) and subcutaneous suture implantation at the withers according to group assignment, 10 animals from each group were euthanized for implanted sutures mechanical testing and histological examination. <b>Results:</b> The inflammatory reaction in the AWD closure area was maximal and significantly different from the subcutaneous implantation by week 3 for all groups. At six weeks, the tissue reaction did not depend on the place of implantation. However, four rats from the Maxon<sup>TM</sup> group demonstrated suture failure with diastasis formation. Non-absorbable barbed sutures exhibited an absence of suture failure and the maximum scar thickness. Both intact absorbable materials (V-Loc<sup>TM</sup> 180 and Maxon<sup>TM</sup>) exhibited a significant breaking strength margin over the non-absorbable. By week 6, the preserved strength of the V-loc<sup>TM</sup> 180 sutures at the AWD was 33% (15-58%), and under the skin-49.7% (48-59%) (<i>p</i> = 0.005). For Maxon<sup>TM</sup>, these values were 38% (35-48%) for the AWD and 44% (34-49%) for the subcutaneous implantation. <b>Conclusions:</b> Absorbable and non-absorbable suture materials, depending on the conditions and timing of implantation, cause various tissue reactions which could affect the wound healing and the number of postoperative complications.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-05-01
DOI
https://doi.org/10.3390/jcm14093139
Citations
2
Primary Topic
Hernia repair and management
Type
article
Field-Weighted Citation Impact
4.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Barbed and Non-Barbed Suture Materials for Ventral Hernia Repair: An Experimental Study

S. Titkova, A. V. Andriyashkin, Г. Б. Ивахов, Alexander Vyacheslavovich Sazhin et al.
2 citations
Journal of Clinical Medicine
Hernia repair and management
4.01
article

Barbed and Non-Barbed Suture Materials for Ventral Hernia Repair: An Experimental Study

S. Titkova, A. V. Andriyashkin, Г. Б. Ивахов, Alexander Vyacheslavovich Sazhin, Konstantin I. Shadin, Aleksandra A. Kalınına, M. Anurov, V.V. Suglob
article en
2 citations

Abstract

<b>Objectives:</b> The objective of this study was to assess the tissue response and strength of traditional and unidirectional suture materials, depending on the conditions of use and the timing following implantation. <b>Methods:</b> Eighty male Wistar rats were randomly assigned to four groups depending on the suture used: unidirectional absorbable V-loc<sup>TM</sup> 180 or non-absorbable V-loc<sup>TM</sup> PBT and traditional absorbable Maxon<sup>TM</sup> or non-absorbable Novafil<sup>TM</sup>. Three and six weeks following the closure of the abdominal wall defect (AWD) and subcutaneous suture implantation at the withers according to group assignment, 10 animals from each group were euthanized for implanted sutures mechanical testing and histological examination. <b>Results:</b> The inflammatory reaction in the AWD closure area was maximal and significantly different from the subcutaneous implantation by week 3 for all groups. At six weeks, the tissue reaction did not depend on the place of implantation. However, four rats from the Maxon<sup>TM</sup> group demonstrated suture failure with diastasis formation. Non-absorbable barbed sutures exhibited an absence of suture failure and the maximum scar thickness. Both intact absorbable materials (V-Loc<sup>TM</sup> 180 and Maxon<sup>TM</sup>) exhibited a significant breaking strength margin over the non-absorbable. By week 6, the preserved strength of the V-loc<sup>TM</sup> 180 sutures at the AWD was 33% (15-58%), and under the skin-49.7% (48-59%) (<i>p</i> = 0.005). For Maxon<sup>TM</sup>, these values were 38% (35-48%) for the AWD and 44% (34-49%) for the subcutaneous implantation. <b>Conclusions:</b> Absorbable and non-absorbable suture materials, depending on the conditions and timing of implantation, cause various tissue reactions which could affect the wound healing and the number of postoperative complications.

Journal of Clinical MedicineVol. 14(9)
Pirogov Russian National Research Medical University (RU), City Clinical Hospital (RU)
Openalex Percentile: Top 8%
Hernia repair and management
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.