Towards a quantum realization of the ampere using single-electron resolution Skipper-CCDs

Abstract This paper presents a proof-of-concept demonstration of the Skipper-charge coupled device (CCD), a sensor with single-electron counting capability, as a promising technology for implementing an electron-pump-based current source. Relying on its single-electron resolution and built-in charge sensing, it allows self-calibration of the charge packets. This article presents an initial discussion of the uncertainty in the charge measurement and achievable currents levels with this technology. We report experimental results that illustrate the key functionalities in manipulating both small and large electron charge packets, including a comparison of the charge generated, self-measured, and drained by the sensor against measurements from an electrometer. These results were obtained using a standard sensor and readout electronics without specific optimizations for this application. The objective is to explore the potential of Skipper-CCD for realizing an electron-based current source.

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-05-01
DOI
https://doi.org/10.1088/1681-7575/add302
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards a quantum realization of the ampere using single-electron resolution Skipper-CCDs

Javier Tiffenberg, Agustín J. Lapi, Guillermo Fernández Moroni, Fernando Chierchie et al.
Metrologia
CCD and CMOS Imaging Sensors
article

Towards a quantum realization of the ampere using single-electron resolution Skipper-CCDs

Javier Tiffenberg, Agustín J. Lapi, Guillermo Fernández Moroni, Fernando Chierchie, Brenda A. Cervantes-Vergara, Blas J. Irigoyen Gimenez, Miqueas E. Gamero, Gustavo Cancelo, J. Estrada, Eduardo Paolini
article en

Abstract

Abstract This paper presents a proof-of-concept demonstration of the Skipper-charge coupled device (CCD), a sensor with single-electron counting capability, as a promising technology for implementing an electron-pump-based current source. Relying on its single-electron resolution and built-in charge sensing, it allows self-calibration of the charge packets. This article presents an initial discussion of the uncertainty in the charge measurement and achievable currents levels with this technology. We report experimental results that illustrate the key functionalities in manipulating both small and large electron charge packets, including a comparison of the charge generated, self-measured, and drained by the sensor against measurements from an electrometer. These results were obtained using a standard sensor and readout electronics without specific optimizations for this application. The objective is to explore the potential of Skipper-CCD for realizing an electron-based current source.

MetrologiaVol. 62(3)
Fermi National Accelerator Laboratory (US), Consejo Nacional de Investigaciones Científicas y Técnicas (AR), Centro Científico Tecnológico - La Plata (AR), Universidad Nacional del Sur (AR), Universidad Nacional de La Plata (AR)
Openalex Percentile: Top 93%
CCD and CMOS Imaging Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Towards a quantum realization of the ampere using single-electron resolution Skipper-CCDs — Javier Tiffenberg, Agustín J. Lapi, et al. · Metrologia (2025) | TGRS Research Map | TGRS