Enhanced temperature control performance in underground refuge chambers through optimization of air inlets layout

• A validated numerical model was employed to investigate the impact of air inlets layout on temperature control performance. • The temperature control performance of ventilation under typical ventilation layout is obtained. • The duration of effective temperature control and the indoor air temperature are primarily influenced by the efficiency of waste heat dissipation. • The optimized application of the ventilation temperature control scheme in refuge chambers. When the underground refuge chamber (URC) operates in the deep sections of mine, it frequently fails to effectively address the issue of indoor environment regulation. The ventilation system can effectively regulate the indoor air quality, serving as a cooling measure as well. An appropriately designed ventilation layout can enhance the uniformity of indoor temperature distribution, thereby improving temperature control performance. In this study, the accuracy of numerical simulation model was validated through experimental method. Numerical simulation was employed to analyze the impact of four factors on the temperature control performance of ventilation system: the distance between inlet and wall (DIW), the type of distance in adjacent inlets (TDIs), the angle of inlet in x-direction and y-direction. The results indicate that: (1) The ventilation layout in case 3 is the most effective. With an initial ambient temperature of 27 °C, the effective temperature control duration is extended by 28 h compared to the typical ventilation scheme, reaching 79 h. Additionally, the temperature at 96 h was reduced by 0.4 °C, and the waste heat emission efficiency improved by 9.67 %. (2) Given that the alteration of the ventilation layout has a minimal impact on the waste heat absorption efficiency, the variation in the heating rate is predominantly influenced by the waste heat emission efficiency. Consequently, waste heat emission efficiency is utilized to analyze the ranking of the four influencing factors of air inlets layout, which are ordered as follows: x-direction > DIW > TDIs > y -direction.

Authors

Institutions

Publication Details

Journal
Building and Environment
Published
2025-05-01
DOI
https://doi.org/10.1016/j.buildenv.2025.113109
Citations
2
Primary Topic
Safety and Risk Management
Type
article
Field-Weighted Citation Impact
5.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced temperature control performance in underground refuge chambers through optimization of air inlets layout

Ruiyong Mao, Zujing Zhang, Jiri Zhou, Hongwei Wu et al.
2 citations
Building and Environment
Safety and Risk Management
5.53
article

Enhanced temperature control performance in underground refuge chambers through optimization of air inlets layout

Ruiyong Mao, Zujing Zhang, Jiri Zhou, Hongwei Wu, Haishan Yang, Xing Liang
article en
2 citations

Abstract

• A validated numerical model was employed to investigate the impact of air inlets layout on temperature control performance. • The temperature control performance of ventilation under typical ventilation layout is obtained. • The duration of effective temperature control and the indoor air temperature are primarily influenced by the efficiency of waste heat dissipation. • The optimized application of the ventilation temperature control scheme in refuge chambers. When the underground refuge chamber (URC) operates in the deep sections of mine, it frequently fails to effectively address the issue of indoor environment regulation. The ventilation system can effectively regulate the indoor air quality, serving as a cooling measure as well. An appropriately designed ventilation layout can enhance the uniformity of indoor temperature distribution, thereby improving temperature control performance. In this study, the accuracy of numerical simulation model was validated through experimental method. Numerical simulation was employed to analyze the impact of four factors on the temperature control performance of ventilation system: the distance between inlet and wall (DIW), the type of distance in adjacent inlets (TDIs), the angle of inlet in x-direction and y-direction. The results indicate that: (1) The ventilation layout in case 3 is the most effective. With an initial ambient temperature of 27 °C, the effective temperature control duration is extended by 28 h compared to the typical ventilation scheme, reaching 79 h. Additionally, the temperature at 96 h was reduced by 0.4 °C, and the waste heat emission efficiency improved by 9.67 %. (2) Given that the alteration of the ventilation layout has a minimal impact on the waste heat absorption efficiency, the variation in the heating rate is predominantly influenced by the waste heat emission efficiency. Consequently, waste heat emission efficiency is utilized to analyze the ranking of the four influencing factors of air inlets layout, which are ordered as follows: x-direction > DIW > TDIs > y -direction.

Building and EnvironmentVol. 280
University of Hertfordshire (GB), Guizhou University (CN), Kingston University London (GB), China South Industries Group (China) (CN)
Climate action
Openalex Percentile: Top 5%
Safety and Risk Management
5.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.