Temperature-dependent microfluidic impedance spectroscopy for non-invasive biofluid characterization

Remote health monitoring has the potential to enable individuals to take control of their own health and well-being and to facilitate a transition toward preventative and personalized healthcare. Sweat can be sampled non-invasively and contains a wealth of information about the metabolic state of an individual, making it an excellent candidate for remote health monitoring. An accurate, rapid, and low-cost biofluid characterization technique is required to enable the widespread use of remote health monitoring. We previously introduced microfluidic impedance spectroscopy for the detection of electrolyte concentration in fluids, whereby a novel device architecture, measurement method, and analysis technique were presented for the characterization of cationic species. The purely electrical nature of this measurement technique removes the intermediate steps inherent in common rival technologies such as optical and electrochemical sensing, offering a range of advantages. In this work, we investigate the effect of temperature on microfluidic impedance spectroscopy of ionic species commonly present in biofluids. We find that the impedance spectra and concentration determination are temperature-dependent; remote health monitoring devices must be calibrated appropriately as they are likely to experience temperature fluctuations. Importantly, we demonstrate the ability of the method to measure the concentration of anionic species alongside that of cationic species, enabling the detection of chloride and lactate, which are useful biomarkers for hydration, cystic fibrosis, fatigue, sepsis, and hypoperfusion. We show that the presence of neutral species does not impair accurate determination of ionic concentration, thus, demonstrating the suitability of microfluidic impedance spectroscopy for non-invasive biofluid characterization.

Authors

Institutions

Publication Details

Journal
Biomicrofluidics
Published
2025-05-01
DOI
https://doi.org/10.1063/5.0255847
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature-dependent microfluidic impedance spectroscopy for non-invasive biofluid characterization

Tom Wade, Sohini Kar‐Narayan
2 citations
Biomicrofluidics
Analytical Chemistry and Sensors
1.47
article

Temperature-dependent microfluidic impedance spectroscopy for non-invasive biofluid characterization

Tom Wade, Sohini Kar‐Narayan
article en
2 citations

Abstract

Remote health monitoring has the potential to enable individuals to take control of their own health and well-being and to facilitate a transition toward preventative and personalized healthcare. Sweat can be sampled non-invasively and contains a wealth of information about the metabolic state of an individual, making it an excellent candidate for remote health monitoring. An accurate, rapid, and low-cost biofluid characterization technique is required to enable the widespread use of remote health monitoring. We previously introduced microfluidic impedance spectroscopy for the detection of electrolyte concentration in fluids, whereby a novel device architecture, measurement method, and analysis technique were presented for the characterization of cationic species. The purely electrical nature of this measurement technique removes the intermediate steps inherent in common rival technologies such as optical and electrochemical sensing, offering a range of advantages. In this work, we investigate the effect of temperature on microfluidic impedance spectroscopy of ionic species commonly present in biofluids. We find that the impedance spectra and concentration determination are temperature-dependent; remote health monitoring devices must be calibrated appropriately as they are likely to experience temperature fluctuations. Importantly, we demonstrate the ability of the method to measure the concentration of anionic species alongside that of cationic species, enabling the detection of chloride and lactate, which are useful biomarkers for hydration, cystic fibrosis, fatigue, sepsis, and hypoperfusion. We show that the presence of neutral species does not impair accurate determination of ionic concentration, thus, demonstrating the suitability of microfluidic impedance spectroscopy for non-invasive biofluid characterization.

BiomicrofluidicsVol. 19(3)
University of Cambridge (GB)
UK Research and Innovation, Engineering and Physical Sciences Research Council
Life in Land
Openalex Percentile: Top 20%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Temperature-dependent microfluidic impedance spectroscopy for non-invasive biofluid characterization — Tom Wade, Sohini Kar‐Narayan · Biomicrofluidics (2025) | TGRS Research Map | TGRS