Resonance Current Suppression for AC-DC Active-Clamp Flyback Converter by Triangular Current Mode

This paper proposes the conduction loss reduction control method under Zero Voltage Switching (ZVS) operation of an AC-DC active-clamp flyback (ACF) converter for USB-Power Delivery. The proposed control method reduces the resonance current in the active clamp circuit by the reduction on-time of the clamp switch, while Triangular Current Mode control achieves ZVS to reduce the switching loss of the ACF converter. Moreover, the proposed control method provides the Power Factor Correction (PFC) capability without an additional PFC circuit because the proposed control method controls the input current by adjusting the on-time of the primary-side switch of the flyback converter. The detailed operation mode of both the conventional control method and the proposed control method is described. Experimental results of the 100-W active-clamp flyback converter demonstrate that the proposed method reduces the RMS current in the active-clamp circuit by 52.7% compared with the conventional control method.

Authors

Institutions

Publication Details

Published
2025-03-16
DOI
https://doi.org/10.1109/apec48143.2025.10977304
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resonance Current Suppression for AC-DC Active-Clamp Flyback Converter by Triangular Current Mode

Jun‐ichi Itoh, Yasuo Uchida, Hiroki Watanabe
Advanced DC-DC Converters
article

Resonance Current Suppression for AC-DC Active-Clamp Flyback Converter by Triangular Current Mode

Jun‐ichi Itoh, Yasuo Uchida, Hiroki Watanabe
article en

Abstract

This paper proposes the conduction loss reduction control method under Zero Voltage Switching (ZVS) operation of an AC-DC active-clamp flyback (ACF) converter for USB-Power Delivery. The proposed control method reduces the resonance current in the active clamp circuit by the reduction on-time of the clamp switch, while Triangular Current Mode control achieves ZVS to reduce the switching loss of the ACF converter. Moreover, the proposed control method provides the Power Factor Correction (PFC) capability without an additional PFC circuit because the proposed control method controls the input current by adjusting the on-time of the primary-side switch of the flyback converter. The detailed operation mode of both the conventional control method and the proposed control method is described. Experimental results of the 100-W active-clamp flyback converter demonstrate that the proposed method reduces the RMS current in the active-clamp circuit by 52.7% compared with the conventional control method.

Nagaoka University of Technology (JP)
Affordable and clean energy
Openalex Percentile: Top 93%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.