Overview of Dynamic Characterization of Switches for Three Phase Voltage Source, Current Source, and Matrix Converter Applications

The double pulse test (DPT) is a widely accepted method to evaluate the dynamic performance of power devices. However, the results are accurate only if the DPT setup emulates the commutation loop. This paper presents an overview of DPT methods for three-phase two-level voltage source, two-level current source, and direct matrix converter applications. The design criteria for the three DPT circuits are presented. Probe selection and the impact of switching voltage-current (V-I) timing misalignment on the testing results are discussed, and a V-I alignment approach is introduced for all the DPT systems. A 1.2 kV/15 A SiC-based DPT presents the results for the three configurations. The impact of parasitic capacitances on the switching losses and the methods to minimize the effect on the DPT results are finally presented.

Authors

Institutions

Publication Details

Published
2025-03-16
DOI
https://doi.org/10.1109/apec48143.2025.10977108
Citations
1
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Overview of Dynamic Characterization of Switches for Three Phase Voltage Source, Current Source, and Matrix Converter Applications

Subhashish Bhattacharya, Sneha Narasimhan, Sathya Rupan Thirumoorthi
1 citations
Electric Motor Design and Analysis
0.73
article

Overview of Dynamic Characterization of Switches for Three Phase Voltage Source, Current Source, and Matrix Converter Applications

Subhashish Bhattacharya, Sneha Narasimhan, Sathya Rupan Thirumoorthi
article en
1 citations

Abstract

The double pulse test (DPT) is a widely accepted method to evaluate the dynamic performance of power devices. However, the results are accurate only if the DPT setup emulates the commutation loop. This paper presents an overview of DPT methods for three-phase two-level voltage source, two-level current source, and direct matrix converter applications. The design criteria for the three DPT circuits are presented. Probe selection and the impact of switching voltage-current (V-I) timing misalignment on the testing results are discussed, and a V-I alignment approach is introduced for all the DPT systems. A 1.2 kV/15 A SiC-based DPT presents the results for the three configurations. The impact of parasitic capacitances on the switching losses and the methods to minimize the effect on the DPT results are finally presented.

North Carolina State University (US)
Affordable and clean energy
Openalex Percentile: Top 29%
Electric Motor Design and Analysis
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.