Small-Signal Analysis and External Ramp Design for Multiphase Current-Mode Constant On-Time Control with Phase Overlapping

High-current processor core voltage regulators (VRs) use current-mode constant on-time (COT) control to simplify phase interleaving and achieve high control bandwidth. Reducing VR bus voltage and increasing phase count results in steady-state phase overlapping within their operating duty range. With phase overlap, a smaller external ramp reduces the inner current loop stability margin and introduces large magnitude peaks in control-to-output response. These peaks could lead to double crossover, reduce gain margin, and make high-bandwidth outer voltage loop unstable in phase overlapping regions. Increasing the ramp damps these peaks and improves the gain margin but reduces the phase margin at the target bandwidth. Hence, this paper simplifies infinite-order describing function model and provides external ramp design guidelines to attain desired stability margin at the target bandwidth. The simplified model and small-signal analysis are validated using SIMPLIS simulation and experiments from a six-phase current-mode COT buck converter.

Authors

Institutions

Publication Details

Published
2025-03-16
DOI
https://doi.org/10.1109/apec48143.2025.10977186
Citations
2
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Small-Signal Analysis and External Ramp Design for Multiphase Current-Mode Constant On-Time Control with Phase Overlapping

Qiang Li, Sundaramoorthy Sridhar
2 citations
Advanced DC-DC Converters
1.46
article

Small-Signal Analysis and External Ramp Design for Multiphase Current-Mode Constant On-Time Control with Phase Overlapping

Qiang Li, Sundaramoorthy Sridhar
article en
2 citations

Abstract

High-current processor core voltage regulators (VRs) use current-mode constant on-time (COT) control to simplify phase interleaving and achieve high control bandwidth. Reducing VR bus voltage and increasing phase count results in steady-state phase overlapping within their operating duty range. With phase overlap, a smaller external ramp reduces the inner current loop stability margin and introduces large magnitude peaks in control-to-output response. These peaks could lead to double crossover, reduce gain margin, and make high-bandwidth outer voltage loop unstable in phase overlapping regions. Increasing the ramp damps these peaks and improves the gain margin but reduces the phase margin at the target bandwidth. Hence, this paper simplifies infinite-order describing function model and provides external ramp design guidelines to attain desired stability margin at the target bandwidth. The simplified model and small-signal analysis are validated using SIMPLIS simulation and experiments from a six-phase current-mode COT buck converter.

Virginia Tech (US)
Affordable and clean energy
Openalex Percentile: Top 18%
Advanced DC-DC Converters
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Small-Signal Analysis and External Ramp Design for Multiphase Current-Mode Constant On-Time Control with Phase Overlapping — Qiang Li, Sundaramoorthy Sridhar · (2025) | TGRS Research Map | TGRS