Analog Control of a 2.5 kW GaN Based CRM PFC with Input Filter Optimization

This paper investigates zero-voltage-switching (ZVS) control of a single-phase GaN-based critical-conductionmode (CRM) totem-pole power factor correction (TPFC) in fully analog domain. Critical mode operation is used by the totem-pole PFC rectifier in order to achieve both high frequency operation and hence smaller magnetics while also achieving high efficiency due to soft switching. A digitally controlled CRM TPFC faces challenges due to current sensing delays and zero-current detection (ZCD) sensitivity to high di/dt noise, which complicates ZVS control. For designing a fully analog controlled CRM TPFC, a deadtime optimization is performed over the entire line cycle to minimize the cycle averaged CRM turn-on loss. Furthermore, the design methodology and volume optimization of input electromagnetic interference (EMI) filter for CRM totem-pole PFC converter is proposed. Finally, a 2.5kW GaN-based 120Vac/240Vac to 400V dc totem-pole PFC is demonstrated with 98.12% peak efficiency operating between 70 kHz (near peak) and 460 kHz (near zero) switching frequency.

Authors

Institutions

Publication Details

Published
2025-03-16
DOI
https://doi.org/10.1109/apec48143.2025.10977113
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analog Control of a 2.5 kW GaN Based CRM PFC with Input Filter Optimization

Ayan Mallik, Naveed Ishraq
1 links
Advanced DC-DC Converters
article

Analog Control of a 2.5 kW GaN Based CRM PFC with Input Filter Optimization

Ayan Mallik, Naveed Ishraq
article en

Abstract

This paper investigates zero-voltage-switching (ZVS) control of a single-phase GaN-based critical-conductionmode (CRM) totem-pole power factor correction (TPFC) in fully analog domain. Critical mode operation is used by the totem-pole PFC rectifier in order to achieve both high frequency operation and hence smaller magnetics while also achieving high efficiency due to soft switching. A digitally controlled CRM TPFC faces challenges due to current sensing delays and zero-current detection (ZCD) sensitivity to high di/dt noise, which complicates ZVS control. For designing a fully analog controlled CRM TPFC, a deadtime optimization is performed over the entire line cycle to minimize the cycle averaged CRM turn-on loss. Furthermore, the design methodology and volume optimization of input electromagnetic interference (EMI) filter for CRM totem-pole PFC converter is proposed. Finally, a 2.5kW GaN-based 120Vac/240Vac to 400V dc totem-pole PFC is demonstrated with 98.12% peak efficiency operating between 70 kHz (near peak) and 460 kHz (near zero) switching frequency.

Arizona State University (US)
National Science Foundation
Affordable and clean energy
Openalex Percentile: Top 93%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.