Analog Control of a 2.5 kW GaN Based CRM PFC with Input Filter Optimization
This paper investigates zero-voltage-switching (ZVS) control of a single-phase GaN-based critical-conductionmode (CRM) totem-pole power factor correction (TPFC) in fully analog domain. Critical mode operation is used by the totem-pole PFC rectifier in order to achieve both high frequency operation and hence smaller magnetics while also achieving high efficiency due to soft switching. A digitally controlled CRM TPFC faces challenges due to current sensing delays and zero-current detection (ZCD) sensitivity to high di/dt noise, which complicates ZVS control. For designing a fully analog controlled CRM TPFC, a deadtime optimization is performed over the entire line cycle to minimize the cycle averaged CRM turn-on loss. Furthermore, the design methodology and volume optimization of input electromagnetic interference (EMI) filter for CRM totem-pole PFC converter is proposed. Finally, a 2.5kW GaN-based 120Vac/240Vac to 400V dc totem-pole PFC is demonstrated with 98.12% peak efficiency operating between 70 kHz (near peak) and 460 kHz (near zero) switching frequency.
Authors
- Ayan Mallik (ORCID: https://orcid.org/0000-0002-4007-662X)
- Naveed Ishraq (ORCID: https://orcid.org/0000-0001-6773-4226)
Institutions
- Arizona State University (US)
Publication Details
- Published
- 2025-03-16
- DOI
- https://doi.org/10.1109/apec48143.2025.10977113
- Primary Topic
- Advanced DC-DC Converters
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Science Foundation