A 3D Structure of Single-Sided Cooling Power Module with Low Thermal Resistance and Low Inductance

This paper describes the three-dimensional structure of a single-sided cooling power module that uses a lead frame as a heat conduction path to cool power semiconductor dies on both sides. The proposed structure achieves low thermal resistance and low inductance, improving the efficiency of motor drive inverters. Simulation results show that the thermal resistance is reduced by 18% and the parasitic commutation loop inductance is reduced by 60% compared to the conventional module. The manufacturability of the proposed module is confirmed by fabricating prototypes, and double pulse tests (800 V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">DC</inf>, turn-on current of 300 A, turn-off current of 400 A) validate its electrical performance.

Authors

Institutions

Publication Details

Published
2025-03-16
DOI
https://doi.org/10.1109/apec48143.2025.10977396
Citations
2
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 3D Structure of Single-Sided Cooling Power Module with Low Thermal Resistance and Low Inductance

Hirofumi Hisamochi, Koji Yamaguchi, Yoshiaki Takahashi, Koki Notake
2 citations
Heat Transfer and Optimization
1.43
article

A 3D Structure of Single-Sided Cooling Power Module with Low Thermal Resistance and Low Inductance

Hirofumi Hisamochi, Koji Yamaguchi, Yoshiaki Takahashi, Koki Notake
article en
2 citations

Abstract

This paper describes the three-dimensional structure of a single-sided cooling power module that uses a lead frame as a heat conduction path to cool power semiconductor dies on both sides. The proposed structure achieves low thermal resistance and low inductance, improving the efficiency of motor drive inverters. Simulation results show that the thermal resistance is reduced by 18% and the parasitic commutation loop inductance is reduced by 60% compared to the conventional module. The manufacturability of the proposed module is confirmed by fabricating prototypes, and double pulse tests (800 V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">DC</inf>, turn-on current of 300 A, turn-off current of 400 A) validate its electrical performance.

IHI Corporation (Japan) (JP)
Affordable and clean energy
Openalex Percentile: Top 21%
Heat Transfer and Optimization
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.