A GaN-based Single-Stage Solid-State Transformer Replacement for 40 VA Class 2 Line-Frequency Transformers

Class 2 transformers are common among several low-power applications, including HVAC control systems, doorbells, automatic doors, and much more. These transformers have low peak efficiencies and very high standby losses. We propose a power-electronic alternative with an emphasis on reducing the yearly average power loss based on a use-case load cycle. Using GaN power devices, a single-stage solid-state transformer is designed, focused on reduced overall solution control and complexity, while maximizing standby efficiency through reduced switching and core losses. An optimization model was developed, providing both passive component recommendations and an optimum operating condition for the selected topology. The 40 VA, 120 VAC to 24 VAC, prototype achieves a peak efficiency of 98.8%, a standby loss of 106 mW, and a use-case average yearly power loss of 207 mW; a 17x reduction in the yearly average power loss compared to Class 2 line-frequency transformers.

Authors

Institutions

Publication Details

Published
2025-03-16
DOI
https://doi.org/10.1109/apec48143.2025.10977193
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A GaN-based Single-Stage Solid-State Transformer Replacement for 40 VA Class 2 Line-Frequency Transformers

Charles R. Sullivan, Allen T. Nguyen
1 citations
High voltage insulation and dielectric phenomena
0.52
article

A GaN-based Single-Stage Solid-State Transformer Replacement for 40 VA Class 2 Line-Frequency Transformers

Charles R. Sullivan, Allen T. Nguyen
article en
1 citations

Abstract

Class 2 transformers are common among several low-power applications, including HVAC control systems, doorbells, automatic doors, and much more. These transformers have low peak efficiencies and very high standby losses. We propose a power-electronic alternative with an emphasis on reducing the yearly average power loss based on a use-case load cycle. Using GaN power devices, a single-stage solid-state transformer is designed, focused on reduced overall solution control and complexity, while maximizing standby efficiency through reduced switching and core losses. An optimization model was developed, providing both passive component recommendations and an optimum operating condition for the selected topology. The 40 VA, 120 VAC to 24 VAC, prototype achieves a peak efficiency of 98.8%, a standby loss of 106 mW, and a use-case average yearly power loss of 207 mW; a 17x reduction in the yearly average power loss compared to Class 2 line-frequency transformers.

Dartmouth College (US)
Affordable and clean energy
Openalex Percentile: Top 39%
High voltage insulation and dielectric phenomena
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A GaN-based Single-Stage Solid-State Transformer Replacement for 40 VA Class 2 Line-Frequency Transformers — Charles R. Sullivan, Allen T. Nguyen · (2025) | TGRS Research Map | TGRS