PIR-R Control for Three-Phase Grid-Connected Inverter with Unbalanced Grid Current Correction

Proposed in this paper a proportional-integral-resonant-resonant (PIR-R) control method for a three-phase grid-connected inverter. Unbalanced loads at the point of common coupling (PCC) can disrupt grid current balance and adversely impact other PCC connections, impairing the inverter’s ability to accurately track active and reactive power commands. The PIR-R control integrates PI and PR components for fundamental reference current tracking and second-order harmonic rejection. The first resonant controller component targets the grid frequency, while the second addresses the double-frequency oscillations caused by unbalanced grid currents. Without the need for additional correction devices such as shunt active power filters at the PCC, the PIR-R method ensures effective reference command tracking and corrects unbalanced grid currents. Simulation and experimental results confirm that the PIR-R control provides improved transient response and reduced steady-state error compared to conventional methods.

Authors

Institutions

Publication Details

Published
2025-03-16
DOI
https://doi.org/10.1109/apec48143.2025.10977366
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PIR-R Control for Three-Phase Grid-Connected Inverter with Unbalanced Grid Current Correction

R.M. Nelms, Haneen Ghanayem, Xingyu Yang, Mohammad Alathamneh
Microgrid Control and Optimization
article

PIR-R Control for Three-Phase Grid-Connected Inverter with Unbalanced Grid Current Correction

R.M. Nelms, Haneen Ghanayem, Xingyu Yang, Mohammad Alathamneh
article en

Abstract

Proposed in this paper a proportional-integral-resonant-resonant (PIR-R) control method for a three-phase grid-connected inverter. Unbalanced loads at the point of common coupling (PCC) can disrupt grid current balance and adversely impact other PCC connections, impairing the inverter’s ability to accurately track active and reactive power commands. The PIR-R control integrates PI and PR components for fundamental reference current tracking and second-order harmonic rejection. The first resonant controller component targets the grid frequency, while the second addresses the double-frequency oscillations caused by unbalanced grid currents. Without the need for additional correction devices such as shunt active power filters at the PCC, the PIR-R method ensures effective reference command tracking and corrects unbalanced grid currents. Simulation and experimental results confirm that the PIR-R control provides improved transient response and reduced steady-state error compared to conventional methods.

Al-Balqa Applied University (JO), Auburn University (US)
Affordable and clean energy
Openalex Percentile: Top 90%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

PIR-R Control for Three-Phase Grid-Connected Inverter with Unbalanced Grid Current Correction — R.M. Nelms, Haneen Ghanayem, et al. · (2025) | TGRS Research Map | TGRS