Comparative Analysis of Carbon Footprints and Material Usage of Solid-State Transformers and Low-Frequency-Transformer-Based MVac-LVdc Interfaces for High-Power EV Charging

Medium-voltage (MV) ac to low-voltage (LV) dc conversion for, e.g., high-power EV charging can be realized either with a low-frequency transformer (LFT) and a downstream LV ac-dc converter, or, alternatively, as a modular solid-state transformer (SST) that employs high-frequency (HF) transformers to provide galvanic isolation. Both solutions achieve similar power conversion efficiencies in the order of 98% but differ significantly regarding complexity and the types and amounts of employed components and materials. Thus, this paper compares the two approaches regarding the embodied carbon footprint and the material usage, on the basis of industrial 400 kW first-generation and 1200 kW second-generation SST demonstrators, highlighting the potential of SST technology to benefit from improvements in power electronics whereas the LFT-based solutions remain constrained by high material usage for the transformer. Specifically, the 1200 kW second-generation SST demonstrator features only about 40% of the mass (2 kg/kW) and about 2/3 of the embodied carbon footprint (13.7 kg CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>eq/kW) of an equally rated LFT-based solution.

Authors

Institutions

Publication Details

Published
2025-03-16
DOI
https://doi.org/10.1109/apec48143.2025.10977184
Citations
2
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Carbon Footprints and Material Usage of Solid-State Transformers and Low-Frequency-Transformer-Based MVac-LVdc Interfaces for High-Power EV Charging

Jonas Huber, Peter Barbosa, Anup Anurag, Johann W. Kolar et al.
2 citations
Electrical Contact Performance and Analysis
1.43
article

Comparative Analysis of Carbon Footprints and Material Usage of Solid-State Transformers and Low-Frequency-Transformer-Based MVac-LVdc Interfaces for High-Power EV Charging

Jonas Huber, Peter Barbosa, Anup Anurag, Johann W. Kolar, Rudy Wang, Luc Imperiali
article en
2 citations

Abstract

Medium-voltage (MV) ac to low-voltage (LV) dc conversion for, e.g., high-power EV charging can be realized either with a low-frequency transformer (LFT) and a downstream LV ac-dc converter, or, alternatively, as a modular solid-state transformer (SST) that employs high-frequency (HF) transformers to provide galvanic isolation. Both solutions achieve similar power conversion efficiencies in the order of 98% but differ significantly regarding complexity and the types and amounts of employed components and materials. Thus, this paper compares the two approaches regarding the embodied carbon footprint and the material usage, on the basis of industrial 400 kW first-generation and 1200 kW second-generation SST demonstrators, highlighting the potential of SST technology to benefit from improvements in power electronics whereas the LFT-based solutions remain constrained by high material usage for the transformer. Specifically, the 1200 kW second-generation SST demonstrator features only about 40% of the mass (2 kg/kW) and about 2/3 of the embodied carbon footprint (13.7 kg CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>eq/kW) of an equally rated LFT-based solution.

Delta Air Lines (United States) (US), ETH Zurich (CH)
Openalex Percentile: Top 21%
Electrical Contact Performance and Analysis
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative Analysis of Carbon Footprints and Material Usage of Solid-State Transformers and Low-Frequency-Transformer-Based MVac-LVdc Interfaces for High-Power EV Charging — Jonas Huber, Peter Barbosa, et al. · (2025) | TGRS Research Map | TGRS