Circulating Current Control with Loss Reduction for Parallel Connected Inverters

Connecting inverters in parallel is a common method for increasing current capacity. Due to the difference in the delay time and on-voltage of the gate circuit and the switching element between the parallel inverters, a circulating current is generated between the inverters connected in parallel. In this paper, we propose a method to suppress the circulating current of a parallel inverter and to reduce the loss. By adjusting the turn-on and turn-off timing, the voltage difference between the inverters is reduced. As a result, the circulation current is suppressed. The effect of the proposed method of adjusting the turn-on delay time by matching the turn-off delay time was experimentally verified. By adjusting the turn-on and turn-off timing, the voltage difference between the inverters is eliminated, the circulating current is suppressed, and the current imbalance rate is less than 1%. It was experimentally verified that increasing the turn-on delay time difference from 39 ns to 76 ns and narrowing the turn-off delay time difference from 43 ns to 3 ns could reduce total switching losses by 3.5%.

Authors

Institutions

Publication Details

Published
2025-03-16
DOI
https://doi.org/10.1109/apec48143.2025.10977493
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Circulating Current Control with Loss Reduction for Parallel Connected Inverters

Naoto Onuma, Shun Endo, Yuichi Mabuchi, Nobuyuki Takayama et al.
Multilevel Inverters and Converters
article

Circulating Current Control with Loss Reduction for Parallel Connected Inverters

Naoto Onuma, Shun Endo, Yuichi Mabuchi, Nobuyuki Takayama, Masato Ando, Yohei Matsumoto, Takae Shimada, Masaki Miyamae
article en

Abstract

Connecting inverters in parallel is a common method for increasing current capacity. Due to the difference in the delay time and on-voltage of the gate circuit and the switching element between the parallel inverters, a circulating current is generated between the inverters connected in parallel. In this paper, we propose a method to suppress the circulating current of a parallel inverter and to reduce the loss. By adjusting the turn-on and turn-off timing, the voltage difference between the inverters is reduced. As a result, the circulation current is suppressed. The effect of the proposed method of adjusting the turn-on delay time by matching the turn-off delay time was experimentally verified. By adjusting the turn-on and turn-off timing, the voltage difference between the inverters is eliminated, the circulating current is suppressed, and the current imbalance rate is less than 1%. It was experimentally verified that increasing the turn-on delay time difference from 39 ns to 76 ns and narrowing the turn-off delay time difference from 43 ns to 3 ns could reduce total switching losses by 3.5%.

Hitachi (Japan) (JP)
Affordable and clean energy
Openalex Percentile: Top 93%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Circulating Current Control with Loss Reduction for Parallel Connected Inverters — Naoto Onuma, Shun Endo, et al. · (2025) | TGRS Research Map | TGRS