DC-Link Voltage Reduction with Synergetic Common-Mode Voltage Control of Single-Phase Two-Stage Non-Isolated EV Chargers

As interest in climate issues grows, research on electric vehicles (EVs) and their charging technologies is advancing. Non-isolated topologies have been proposed to improve EV charger efficiency and power density. However, removing the galvanic isolation stage increases leakage currents, potentially causing electric shocks to users. These currents, generated by low-frequency (LF) common-mode voltage (CMV), are difficult to attenuate with EMI filters. Injecting LF CMV into the power converter can reduce leakage currents but requires higher DC-link voltage, increasing losses and reducing efficiency. This paper proposes a two-stage non-isolated EV charger with an AC/DC power factor correction (PFC) converter and a DC/DC three-level regulator. The PFC and regulator synergistically share the CMV to lower the DC-link voltage while maintaining leakage current reduction. The proposed method enables operation at lower DC-link voltage and higher modulation index (MI) regions. Experimental validation using a prototype confirms its effectiveness.

Authors

Institutions

Publication Details

Published
2025-03-16
DOI
https://doi.org/10.1109/apec48143.2025.10977561
Citations
2
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
1.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DC-Link Voltage Reduction with Synergetic Common-Mode Voltage Control of Single-Phase Two-Stage Non-Isolated EV Chargers

Dongsu Lee, Jung-Ik Ha, Juwon Lee
2 citations
Advanced Battery Technologies Research
1.37
article

DC-Link Voltage Reduction with Synergetic Common-Mode Voltage Control of Single-Phase Two-Stage Non-Isolated EV Chargers

Dongsu Lee, Jung-Ik Ha, Juwon Lee
article en
2 citations

Abstract

As interest in climate issues grows, research on electric vehicles (EVs) and their charging technologies is advancing. Non-isolated topologies have been proposed to improve EV charger efficiency and power density. However, removing the galvanic isolation stage increases leakage currents, potentially causing electric shocks to users. These currents, generated by low-frequency (LF) common-mode voltage (CMV), are difficult to attenuate with EMI filters. Injecting LF CMV into the power converter can reduce leakage currents but requires higher DC-link voltage, increasing losses and reducing efficiency. This paper proposes a two-stage non-isolated EV charger with an AC/DC power factor correction (PFC) converter and a DC/DC three-level regulator. The PFC and regulator synergistically share the CMV to lower the DC-link voltage while maintaining leakage current reduction. The proposed method enables operation at lower DC-link voltage and higher modulation index (MI) regions. Experimental validation using a prototype confirms its effectiveness.

Seoul National University (KR)
Electric Power Research Institute, National Research Foundation
Affordable and clean energy
Openalex Percentile: Top 20%
Advanced Battery Technologies Research
1.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.