Parahydrogen-Hyperpolarized Propane-<i>d</i><sub>6</sub> Gas Contrast Agent: <i>T</i><sub>1</sub> Relaxation Dynamics and Pilot Millimeter-Scale Ventilation MRI

Hyperpolarized (HP) MRI provides enhanced signals over conventional MRI due to the increase in nuclear spin polarization by orders of magnitude compared to thermal polarization. Therefore, HP MRI can be successfully utilized toward imaging of low-density gases in void spaces, such as human lungs. Specifically, in clinical pulmonary imaging, HP MRI employs a gaseous contrast agent that fills the lungs during inhalation under physiologically relevant conditions prior to imaging. FDA-approved HP <sup>129</sup>Xe gas can now be used as the first HP inhalable gaseous contrast agent for functional lung imaging in adults and pediatric patients above 12 years for diagnosis and monitoring responses to the treatment of many pulmonary diseases. However, despite the substantial success of HP <sup>129</sup>Xe in research settings, the production and MRI of this novel contrast agent remain expensive and not universally available on clinical MRI scanners. An alternative approach is to deploy a proton-hyperpolarized gas that is cheap and fast to produce and can be detected on any clinical MRI scanner without any modification. Hyperpolarized propane gas has recently emerged as a potential next-generation hyperpolarized inhalable contrast agent. Here, the relaxation dynamics of two deuterated hyperpolarized propane isotopologues have been explored at clinically relevant conditions of 1 atm gas pressure and 0.35 and 1.4 T magnetic fields using pairwise addition of parahydrogen to a corresponding unsaturated precursor over the heterogeneous Rh/TiO<sub>2</sub> catalyst. The <i>T</i><sub>1</sub> relaxation time of HP propane-<i>d</i><sub>6</sub> gas (0.91±0.03 s) at 1.4 T was found to be similar to that of HP propane gas (0.81±0.06 s) because the dominating relaxation mechanism is due to the coupling of the nuclear spins to the molecular rotation of these two propane gas isotopologues. Moreover, the effective polarization decay constant increases for HP propane-<i>d</i><sub>6</sub> to 1.35±0.05 s (and for HP propane to 1.35±0.10 s) at 0.35 T, pointing to the likely "partial" presence of the long-lived spin states (LLSS) at this clinically relevant field, corresponding to the intermediate spin-spin coupling regime of the two parahydrogen-derived hyperpolarized sites. Furthermore, the pilot feasibility of rapid lung ventilation imaging with 1 × 1 × 9 mm<sup>2</sup> voxel-size spatial resolution using a clinical 0.35 T open MRI scanner was demonstrated by inflating HP propane-<i>d</i><sub>6</sub> gas in excised rabbit lungs, despite the reduction of the HP gas relaxation constant to 0.78 ± 0.02 s in the lungs.

Authors

Institutions

Publication Details

Journal
The Journal of Physical Chemistry A
Published
2025-05-01
DOI
https://doi.org/10.1021/acs.jpca.4c08800
Citations
13
Primary Topic
Advanced NMR Techniques and Applications
Type
article
Field-Weighted Citation Impact
9.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parahydrogen-Hyperpolarized Propane-d6 Gas Contrast Agent: T1 Relaxation Dynamics and Pilot Millimeter-Scale Ventilation MRI

Md Raduanul H. Chowdhury, Boyd M. Goodson, Igor V. Koptyug, Oleg G. Salnikov et al.
13 citations
The Journal of Physical Chemistry A
Advanced NMR Techniques and Applications
9.83
article

Parahydrogen-Hyperpolarized Propane-d6 Gas Contrast Agent: T1 Relaxation Dynamics and Pilot Millimeter-Scale Ventilation MRI

Md Raduanul H. Chowdhury, Boyd M. Goodson, Igor V. Koptyug, Oleg G. Salnikov, Zhongjie Shi, Juri George Gelovani, Yuri A. Chekmenev, M. Suleiman, Shiraz Nantogma, Anna Samoilenko, Larisa M. Kovtunova, Eduard Y. Chekmenev, Nuwandi M. Ariyasingha, Clementinah Oladun, Kehuan Luo, Sidhartha Tan, Alba Xhupi
article en
13 citations

Abstract

Hyperpolarized (HP) MRI provides enhanced signals over conventional MRI due to the increase in nuclear spin polarization by orders of magnitude compared to thermal polarization. Therefore, HP MRI can be successfully utilized toward imaging of low-density gases in void spaces, such as human lungs. Specifically, in clinical pulmonary imaging, HP MRI employs a gaseous contrast agent that fills the lungs during inhalation under physiologically relevant conditions prior to imaging. FDA-approved HP <sup>129</sup>Xe gas can now be used as the first HP inhalable gaseous contrast agent for functional lung imaging in adults and pediatric patients above 12 years for diagnosis and monitoring responses to the treatment of many pulmonary diseases. However, despite the substantial success of HP <sup>129</sup>Xe in research settings, the production and MRI of this novel contrast agent remain expensive and not universally available on clinical MRI scanners. An alternative approach is to deploy a proton-hyperpolarized gas that is cheap and fast to produce and can be detected on any clinical MRI scanner without any modification. Hyperpolarized propane gas has recently emerged as a potential next-generation hyperpolarized inhalable contrast agent. Here, the relaxation dynamics of two deuterated hyperpolarized propane isotopologues have been explored at clinically relevant conditions of 1 atm gas pressure and 0.35 and 1.4 T magnetic fields using pairwise addition of parahydrogen to a corresponding unsaturated precursor over the heterogeneous Rh/TiO<sub>2</sub> catalyst. The <i>T</i><sub>1</sub> relaxation time of HP propane-<i>d</i><sub>6</sub> gas (0.91±0.03 s) at 1.4 T was found to be similar to that of HP propane gas (0.81±0.06 s) because the dominating relaxation mechanism is due to the coupling of the nuclear spins to the molecular rotation of these two propane gas isotopologues. Moreover, the effective polarization decay constant increases for HP propane-<i>d</i><sub>6</sub> to 1.35±0.05 s (and for HP propane to 1.35±0.10 s) at 0.35 T, pointing to the likely "partial" presence of the long-lived spin states (LLSS) at this clinically relevant field, corresponding to the intermediate spin-spin coupling regime of the two parahydrogen-derived hyperpolarized sites. Furthermore, the pilot feasibility of rapid lung ventilation imaging with 1 × 1 × 9 mm<sup>2</sup> voxel-size spatial resolution using a clinical 0.35 T open MRI scanner was demonstrated by inflating HP propane-<i>d</i><sub>6</sub> gas in excised rabbit lungs, despite the reduction of the HP gas relaxation constant to 0.78 ± 0.02 s in the lungs.

The Journal of Physical Chemistry AVol. 129(19)
Wayne State University (US), The Barbara Ann Karmanos Cancer Institute (US), Boreskov Institute of Catalysis (RU), XeUS Technologies (Cyprus) (CY), International Tomography Center (RU)
National Science Foundation, Wayne State University, Ministry of Science and Higher Education of the Russian Federation, National Heart, Lung, and Blood Institute, National Institute of Neurological Disorders and Stroke, Congressionally Directed Medical Research Programs
Affordable and clean energy
Openalex Percentile: Top 1%
Advanced NMR Techniques and Applications
9.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.