Off-axis endoscope implementation for swept-source full-field optical coherence tomography

This paper presents a novel approach for forward viewing endoscopy based on off-axis swept source full-field optical coherence tomography. In contrast to common OCT endoscope probes, based on side-viewing, we propose a design without electro-optical components, while still able to produce forward-view images. Here, through an analogous setup, we study the effect of the different free parameters of the design, such as input polarization state, off-axis angle, and beam divergence. As a result, we present B-Scans showing the OPD variation while changing the off-axis angle. Overall, we study the impact of the free parameters for optimal working conditions of the proposed endoscope.

Authors

Institutions

Publication Details

Published
2025-03-21
DOI
https://doi.org/10.1117/12.3046461
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Off-axis endoscope implementation for swept-source full-field optical coherence tomography

Alejandro Martínez Jiménez, Adrian Podoleanu, Michael R. Hughes, Hal Dorrington
Optical Coherence Tomography Applications
article

Off-axis endoscope implementation for swept-source full-field optical coherence tomography

Alejandro Martínez Jiménez, Adrian Podoleanu, Michael R. Hughes, Hal Dorrington
article en

Abstract

This paper presents a novel approach for forward viewing endoscopy based on off-axis swept source full-field optical coherence tomography. In contrast to common OCT endoscope probes, based on side-viewing, we propose a design without electro-optical components, while still able to produce forward-view images. Here, through an analogous setup, we study the effect of the different free parameters of the design, such as input polarization state, off-axis angle, and beam divergence. As a result, we present B-Scans showing the OPD variation while changing the off-axis angle. Overall, we study the impact of the free parameters for optimal working conditions of the proposed endoscope.

University of Kent (GB)
Openalex Percentile: Top 91%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.