Retrieval of SO₂ Concentration from UV Camera Image Based on Immuneoassay of Light Dilution Effect

SO<sub>2</sub> UV camera has rapidly become integral in remote sensing applications of polluted gases by virtue of its simple structure, high spatiotemporal resolution, and extensive monitoring range. However, as the monitoring distance increases, atmospheric aerosol scattering induces light dilution effects, which significantly compromise measurement accuracy, and conventional calibration methods face limitations in effectively compensating for light dilution without incurring high instrumentation costs. To overcome these challenges, this paper proposes a light dilution effect-immune calibration method (LDECM) tailored for dual-channel UV camera systems. Instead of measuring the distance and visibility from the UV camera to the emission source, the method utilizes only the raw images acquired by the two channels of the UV camera to retrieve the image of the SO<sub>2</sub> column concentration, which is not affected by the light dilution effect. Results from simulations and field experiments show that this method effectively eliminates the influence of light dilution and distance, and compared with the differential optical absorption spectroscopy (DOAS) calibration method, the retrieval results are very close, with an average error reduction of approximately 5.5%. Additionally, emission rates derived from the SO<sub>2</sub> column amount data produced by both methods show a goodness of fit of 0.95, underscoring the accuracy and reliability of the proposed approach. The proposed light dilution effect-immune calibration method offers operational simplicity and strong spectral adaptability, providing an effective means for remote sensing monitoring of SO<sub>2</sub> gas.

Authors

Publication Details

Journal
Optics Express
Published
2025-05-01
DOI
https://doi.org/10.1364/oe.558289
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retrieval of SO₂ Concentration from UV Camera Image Based on Immuneoassay of Light Dilution Effect

Haochen Yuan, Weiwei He, Wei Zhou, Yikang Zhang et al.
Optics Express
Air Quality Monitoring and Forecasting
article

Retrieval of SO₂ Concentration from UV Camera Image Based on Immuneoassay of Light Dilution Effect

Haochen Yuan, Weiwei He, Wei Zhou, Yikang Zhang, Huiliang Zhang
article en

Abstract

SO<sub>2</sub> UV camera has rapidly become integral in remote sensing applications of polluted gases by virtue of its simple structure, high spatiotemporal resolution, and extensive monitoring range. However, as the monitoring distance increases, atmospheric aerosol scattering induces light dilution effects, which significantly compromise measurement accuracy, and conventional calibration methods face limitations in effectively compensating for light dilution without incurring high instrumentation costs. To overcome these challenges, this paper proposes a light dilution effect-immune calibration method (LDECM) tailored for dual-channel UV camera systems. Instead of measuring the distance and visibility from the UV camera to the emission source, the method utilizes only the raw images acquired by the two channels of the UV camera to retrieve the image of the SO<sub>2</sub> column concentration, which is not affected by the light dilution effect. Results from simulations and field experiments show that this method effectively eliminates the influence of light dilution and distance, and compared with the differential optical absorption spectroscopy (DOAS) calibration method, the retrieval results are very close, with an average error reduction of approximately 5.5%. Additionally, emission rates derived from the SO<sub>2</sub> column amount data produced by both methods show a goodness of fit of 0.95, underscoring the accuracy and reliability of the proposed approach. The proposed light dilution effect-immune calibration method offers operational simplicity and strong spectral adaptability, providing an effective means for remote sensing monitoring of SO<sub>2</sub> gas.

Optics ExpressVol. 33(10)
National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, Project of Shandong Province Higher Educational Science and Technology Program
Openalex Percentile: Top 92%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Retrieval of SO₂ Concentration from UV Camera Image Based on Immuneoassay of Light Dilution Effect — Haochen Yuan, Weiwei He, et al. · Optics Express (2025) | TGRS Research Map | TGRS