Evaluation of MicroScan and VITEK 2 systems for susceptibility testing of Enterobacterales with updated breakpoints

We compared the performance of two commercial antimicrobial susceptibility testing (AST) systems for contemporary Enterobacterales strains using broth microdilution (BMD) as the reference standard with 2022 Clinical and Laboratory Standards Institute or current FDA breakpoints applied. Enterobacterales clinical isolates with BMD results were tested in parallel using VITEK 2 AST test cards (N802, XN15, bioMérieux, Hazelwood, MO, USA) and MicroScan NM56 AST panels (Beckman Coulter, Sacramento, CA, USA). The 200 isolates (57 <i>Escherichia coli</i>, 55 <i>Klebsiella pneumoniae</i>, 21 <i>Enterobacter cloacae</i> complex, 18 <i>Serratia marcescens</i>, 12 <i>Proteus mirabilis</i>, 10 <i>Citrobacter koseri</i>, 9 <i>Citrobacter freundii</i>, 8 <i>Klebsiella oxytoca</i>, 5 <i>Klebsiella aerogenes</i>, 3 <i>Providencia stuartii</i>, and 2 <i>Morganella morganii</i>) included 25% extended-spectrum beta-lactamase (ESBL), 23% carbapenem-resistant Enterobacterales (CRE), and 4.5% AmpC resistance phenotypes. For the 28 antimicrobial agents tested, essential agreement (EA, MIC within ±1 doubling dilution), categorical agreement (CA, same categorical interpretation: susceptible, intermediate, susceptible dose dependent, and resistant), and error rates were calculated using BMD as the reference standard. Time to results (TTR) was determined for each instrument for all 200 isolates. Hands-on time was assessed by timing two technologists each setting up six batches of five isolates on each system. Accuracy was similar between systems with an overall CA > 94% and EA ≥ 96%. The CA was ≥90% for most agents tested on both systems (exceptions were ampicillin-sulbactam, cefoxitin, minocycline, and nitrofurantoin). The MicroScan with Prompt inoculum preparation required less hands-on setup time than VITEK (1.29 vs 1.83 min/isolate). The median instrument TTR was less for VITEK (11.7 vs 18 hours, <i>P</i> < 0.001), yielding an overall faster turnaround time.IMPORTANCEThere are limited data directly comparing the performance of commercial antimicrobial susceptibility testing systems for contemporary bacterial strains using the Clinical and Laboratory Standards Institute broth microdilution method as the reference standard and applying updated breakpoints. These data will hopefully encourage labs to perform the necessary verification or validation studies needed to implement current breakpoints and ensure antimicrobial resistance is detected.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Microbiology
Published
2025-05-01
DOI
https://doi.org/10.1128/jcm.00048-25
Citations
7
Primary Topic
Bacterial Identification and Susceptibility Testing
Type
article
Field-Weighted Citation Impact
9.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of MicroScan and VITEK 2 systems for susceptibility testing of Enterobacterales with updated breakpoints

Shawn H. MacVane, Elena Domı́nguez, Sandra S. Richter, Aaron A. Hupp et al.
7 citations
Journal of Clinical Microbiology
Bacterial Identification and Susceptibility Testing
9.23
article

Evaluation of MicroScan and VITEK 2 systems for susceptibility testing of Enterobacterales with updated breakpoints

Shawn H. MacVane, Elena Domı́nguez, Sandra S. Richter, Aaron A. Hupp, Matt Griffis
article en
7 citations

Abstract

We compared the performance of two commercial antimicrobial susceptibility testing (AST) systems for contemporary Enterobacterales strains using broth microdilution (BMD) as the reference standard with 2022 Clinical and Laboratory Standards Institute or current FDA breakpoints applied. Enterobacterales clinical isolates with BMD results were tested in parallel using VITEK 2 AST test cards (N802, XN15, bioMérieux, Hazelwood, MO, USA) and MicroScan NM56 AST panels (Beckman Coulter, Sacramento, CA, USA). The 200 isolates (57 <i>Escherichia coli</i>, 55 <i>Klebsiella pneumoniae</i>, 21 <i>Enterobacter cloacae</i> complex, 18 <i>Serratia marcescens</i>, 12 <i>Proteus mirabilis</i>, 10 <i>Citrobacter koseri</i>, 9 <i>Citrobacter freundii</i>, 8 <i>Klebsiella oxytoca</i>, 5 <i>Klebsiella aerogenes</i>, 3 <i>Providencia stuartii</i>, and 2 <i>Morganella morganii</i>) included 25% extended-spectrum beta-lactamase (ESBL), 23% carbapenem-resistant Enterobacterales (CRE), and 4.5% AmpC resistance phenotypes. For the 28 antimicrobial agents tested, essential agreement (EA, MIC within ±1 doubling dilution), categorical agreement (CA, same categorical interpretation: susceptible, intermediate, susceptible dose dependent, and resistant), and error rates were calculated using BMD as the reference standard. Time to results (TTR) was determined for each instrument for all 200 isolates. Hands-on time was assessed by timing two technologists each setting up six batches of five isolates on each system. Accuracy was similar between systems with an overall CA > 94% and EA ≥ 96%. The CA was ≥90% for most agents tested on both systems (exceptions were ampicillin-sulbactam, cefoxitin, minocycline, and nitrofurantoin). The MicroScan with Prompt inoculum preparation required less hands-on setup time than VITEK (1.29 vs 1.83 min/isolate). The median instrument TTR was less for VITEK (11.7 vs 18 hours, <i>P</i> < 0.001), yielding an overall faster turnaround time.IMPORTANCEThere are limited data directly comparing the performance of commercial antimicrobial susceptibility testing systems for contemporary bacterial strains using the Clinical and Laboratory Standards Institute broth microdilution method as the reference standard and applying updated breakpoints. These data will hopefully encourage labs to perform the necessary verification or validation studies needed to implement current breakpoints and ensure antimicrobial resistance is detected.

Journal of Clinical MicrobiologyVol. 63(6)
bioMérieux (United States) (US), Mayo Clinic in Arizona (US)
Openalex Percentile: Top 2%
Bacterial Identification and Susceptibility Testing
9.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.